TECHNICAL DATA

32

WATERFLUX 3000

www.krohne.com

06/2013 - 400162663 - HB WATERFLUX 3000 R04 en

6.3.2 Verification to MI-001

Verification to MI-001

INFORMATION!
Verification to MI-001 and OIML R49, standard at the following values for R, Q1, Q2 and Q3.
Verification at other values for R and Q3 available on request.

DN

Span (R)

Flow rate [m

3

/h]

Q1

Q2

Q3

25

80

0.050

0.080

4

32

80

0.125

0.200

10

40

80

0.125

0.200

10

50

80

0.200

0.320

16

65

80

0.313

0.500

25

80

80

0.500

0.800

40

100

80

0.788

1.260

63

125

80

1.250

2.000

100

150

80

2.000

3.200

160

200

80

3.125

5.000

250

250

80

5.000

8.000

400

300

80

7.875

12.600

630