beautypg.com

Technical data – KROHNE WATERFLUX 3000 EN User Manual

Page 27

background image

TECHNICAL DATA

6

27

WATERFLUX 3000

www.krohne.com

06/2013 - 400162663 - HB WATERFLUX 3000 R04 en

Operating conditions

Temperature

Temperature

Temperature

Temperature

Process temperature

-5...+70°C / +23...+158°F

Ambient temperature

Standard

Standard

Standard

Standard (with aluminium converter housing):

-40…+65°C / -40…+149°F

Protect electronics against self-heating at ambient temperatures above

55°C / 130°F

Option

Option

Option

Option (with stainless steel converter housing):

-40…+55°C / -40…+130°F

Storage temperature

-50…+70°C / -58…+158°F

Measurement range

Measurement range

Measurement range

Measurement range

-12...+12 m/s / -40...+40 ft/s

Pressure

Pressure

Pressure

Pressure

Operating pressure

Up to 16 bar / 232 psi for DN25...300

Up to 10 bar / 145 psi for DN350...600

Vacuum load

0 mbar / 0 psi absolute

Pressure loss

For detailed information refer to

Pressure loss

on page 38.

Chemical properties

Chemical properties

Chemical properties

Chemical properties

Physical condition

Water: drinking water, raw water, irrigation water.

For salt water please contact the factory.

Electrical conductivity

≥ 20 μS/cm

Installation conditions

Installation

Assure that the flow sensor is always fully filled.

For detailed information refer to

Installation

on page 12.

Flow direction

Forward and reverse

Arrow on flow sensor indicates forward flow direction.

Inlet run

DN25...300:≥ 0 DN

DN350...600:≥ 3 DN

For detailed information refer to

Measurement accuracy

on page 33.

Outlet run

DN25...300:≥ 0 DN

DN350...600:≥ 1 DN

For detailed information refer to

Measurement accuracy

on page 33.

Dimensions and weights

For detailed information refer to

Dimensions and weights