Technical data – KROHNE WATERFLUX 3000 EN User Manual
Page 26
6
TECHNICAL DATA
26
WATERFLUX 3000
www.krohne.com
06/2013 - 400162663 - HB WATERFLUX 3000 R04 en
Measuring accuracy
Reference conditions
Medium: water
Temperature: +10...+30°C / +50...+86°F
Operating pressure: 1 bar / 14,5 psi
Inlet section ≥ 3 DN; outlet section ≥ 1 DN
Electrical conductivity: ≥ 300 µS / cm
Maximum measuring
error
IFC 050: 0.5% of the measured value above 0.5 m/s,
below 0.5 m/s, deviation ± 2.5 mm/s
DN25...300; IFC 100: down to 0.3% of the measured value ± 0.5 mm/s
DN25...300; IFC 300: down to 0.2% of the measured value ± 0.5 mm/s
DN350...600; IFC 100: down to 0.5% of the measured value ± 1 mm/s
DN350...600; IFC 300: down to 0.4% of the measured value ± 1 mm/s
The maximum measuring error depends on the installation conditions.
For detailed information refer to
Measurement accuracy
on page 33.
Repeatability
DN25...300 ; ±0.1% (v >0.5m/s / 1.5 ft/s)
DN350...600; ±0.2% (v >0.5m/s / 1.5 ft/s)
Calibration / Verification
Standard:
Standard:
Standard:
Standard:
2 point calibration by a direct volume comparison.
Option (for DN25...300):
Option (for DN25...300):
Option (for DN25...300):
Option (for DN25...300):
Verification to Measurement Instrument Directive (MID), Annex MI-001.
Standard: Verification at Ratio (Q3/Q1) = 80, Q3 ≥ 2 m/s
Optional: Verification at Ratio (Q3/Q1) > 80
Only in combination with the IFC 300 signal converter
MID Annex MI-001
(Directive 2004/22/EC)
EC-Type examination certificate to MID Annex MI-001
EC-Type examination certificate to MID Annex MI-001
EC-Type examination certificate to MID Annex MI-001
EC-Type examination certificate to MID Annex MI-001
Only in combination with the IFC 300 signal converter
Diameter range: DN25...300
Minimum straight inlet flow: 0 DN
Minimum straight outlet flow: 0 DN
Forward and reverse (bi-directional) flow
Orientation: any
Ratio (Q3/Q1) upto 400
Liquid temperature range: +0.1°C / 50°C
Maximum operating pressure: ≤ DN200: 16 bar, ≥ DN250: 10 bar
For detailed information refer to
Legal metrology
on page 30.