INSTALLATION

2

5

TIDALFLUX 2300 F

www.krohne.com

06/2013 - 4002489402 - QS TIDALFLUX 2300 R02 en

• Store the device in its original packaging.
• Storage temperature: -50 ...+70°C / -58...+158°F

2.5 Transport

2.6 Pre-installation requirements

Make sure that you have all necessary tools available:

• Allen key (4 mm)
• Small screwdriver
• Wrench for cable glands
• Wrench for wall mounting bracket (remote version only)
• Torque wrench for installing flowmeter in pipeline

2.7 General requirements

Figure 2-3: Transport

INFORMATION!

The following precautions must be taken to ensure reliable installation.

Make sure that there is adequate space to the sides.

Protect the signal converter from direct sunlight and install a sun shade if necessary.

Signal converters installed in control cabinets require adequate cooling, e.g. by fan or heat

exchanger.

Do not expose the signal converter to intense vibration. The flowmeters are tested for a

vibration level in accordance with IEC 68-2-64.

2.4 Storage

• Store the device in a dry and dust-free location.
• Avoid lasting direct exposure to the sun.