Technical data, 1 dimensions and weights – KROHNE TIDALFLUX 2300 F Quickstart EN User Manual
Page 22
4
TECHNICAL DATA
22
TIDALFLUX 2300 F
www.krohne.com
06/2013 - 4002489402 - QS TIDALFLUX 2300 R02 en
4.1 Dimensions and weights
The inner pipe diameter should match the inner diameter of the flowmeter. Since the inner
diameter is not a standard DN size, choose the inner pipe diameter to be just a little bit bigger
than the flowmeter diameter. If a lot of sediment or fat is expected the optimal solution is to
produce a diameter compensation ring on both sides to have smooth transits.
EN 1092-1
k = 230 mm / 89.1"
m = 265 mm / 10.4"
n = 251 mm / 9.9"
INFORMATION!
Detailed 2D and 3D drawings are available on the website of the manufacturer.
Nominal size
Dimensions [mm]
Approx.
weight
[kg]
DN
PN
a
b
Øc
d
ØD
ØD
i
200
10
350
582
291
146
340
189
40
250
10
400
630
331
166
395
231
54
300
10
500
680
381
191
445
281
66
350
10
500
733
428
214
505
316
95
400
10
600
791
483
242
565
365
115
500
10
600
894
585
293
670
467
145
600
10
600
1003
694
347
780
567
180
700
10
700
1120
812
406
895
666
265
800
10
800
1235
922
461
1015
768
350
900
10
900
1356
1064
532
1115
863
425
1000
10
1000
1447
1132
566
1230
965
520
1200
6
1200
1639
1340
670
1405
1169
659
1400
6
1400
1842
1521
761
1630
1367
835
1600
6
1600
2042
1721
861
1830
1549
1659