4.1 Dimensions and weights

The inner pipe diameter should match the inner diameter of the flowmeter. Since the inner
diameter is not a standard DN size, choose the inner pipe diameter to be just a little bit bigger
than the flowmeter diameter. If a lot of sediment or fat is expected the optimal solution is to
produce a diameter compensation ring on both sides to have smooth transits.

EN 1092-1

k = 230 mm / 89.1"

m = 265 mm / 10.4"

n = 251 mm / 9.9"

INFORMATION!
Detailed 2D and 3D drawings are available on the website of the manufacturer.

Nominal size

Dimensions [mm]

Approx.

weight

[kg]

DN

PN

a

b

Øc

d

ØD

ØD

i

200

10

350

582

291

146

340

189

40

250

10

400

630

331

166

395

231

54

300

10

500

680

381

191

445

281

66

350

10

500

733

428

214

505

316

95

400

10

600

791

483

242

565

365

115

500

10

600

894

585

293

670

467

145

600

10

600

1003

694

347

780

567

180

700

10

700

1120

812

406

895

666

265

800

10

800

1235

922

461

1015

768

350

900

10

900

1356

1064

532

1115

863

425

1000

10

1000

1447

1132

566

1230

965

520

1200

6

1200

1639

1340

670

1405

1169

659

1400

6

1400

1842

1521

761

1630

1367

835

1600

6

1600

2042

1721

861

1830

1549

1659