2.8 Installation conditions

2.8.1 Inlet and outlet

2.8.2 Bends in 2 or 3 dimensions

2.8.3 T-section

Figure 2-6: Recommended inlet and outlet

1 Refer to chapter "Bends in 2 or 3 dimensions"
2 ≥ 2 DN

Figure 2-7: 2 and 3 dimensional bends, in front of flowmeter

1 Bends in 2 dimensions: ≥ 5 DN; bends in 3 dimensions: ≥ 10 DN

Figure 2-8: Distance after T-sections

1 ≥ 10 DN