beautypg.com

Installation, 9 mounting, 1 torques and pressures – KROHNE OPTIFLUX 6000 Quickstart EN User Manual

Page 13

background image

INSTALLATION

2

13

OPTIFLUX 6000

www.krohne.com

07/2013 - 4002945701 - QS OPTIFLUX 6000 R05 en

2.9 Mounting

2.9.1 Torques and pressures

Tightening of bolts

• Always tighten the bolts uniformely and in diagonally opposite sequence.
• Do not exceed the maximum torque value.
• Step 1: Apply approx. 50% of max. torque given in table.
• Step 2: Apply approx. 80% of max. torque given in table.
• Step 3: Apply 100% of max. torque given in table.

Maximum torque for 11864-2A flange version

Figure 2-19: Tightening of bolts

CAUTION!
The max. allowable torque depends on the gasket material, see datasheet for detailed
information.
Bolts to be used from material SS, class 70-A2.

Nominal diameter

[mm]

Pressure rating

Bolts

Max. torque

[Nm]

25

PN 40

4x M6

7

40

PN 40

4x M8

16

50

PN 25

4x M8

16

80

PN 25

6x M8

16

100

PN 25

6x M8

16

125

PN 10

6x M10

32

150

PN 10

6x M10

32