beautypg.com

Reversing timer spin/dwell adjustments – American Dryer Corp. AD-75V User Manual

Page 49

background image

45

SECTION VIII

REVERSING TIMER SPIN/DWELL ADJUSTMENTS

Dual timer models with “reversing option” have an electric reversing timer in the electric service box, which is
located in the upper rear area of the dryer.

Both dwell (stop) time and basket (tumbler) spin time are adjustable by mode selection switches located on the
electronic timer (as noted in the illustration below).

SPIN TIME

Adjustment Position Number

1

2

3

4

5

Time in Seconds*

30

60

90

120

150

DWELL (STOP) TIME

Adjustment Position Number

1

2

3

4

5

Time in Seconds*

5

6.3

7.6

8.9

10.2

* Values shown are +/- 1-second.