5.0 Specifications


Input Power

9 to 30VDC (Nominal 24VDC)


Power Consumption (per channel)

100mA Maximum (Including Sensor)

3W Maximum (Including Sensor)


Operating Temperature

–40°C to +85°C

Humidity: 10 to 95% Non-condensing


Outputs

Analog 4-20mA DC

HART

®

Communication Protocol

HART

®

Version

7.0

Manufacturer ID
0x6007

Device ID
0xE08B

Warranty
One

year

Five year fixed fee service policy




6.0 Warranty


All warranties are FOB the Detcon factory. Should any product fail to perform in accordance with published
specifications within the warranty period, return it freight pre-paid to Detcon Inc., 3200 Research Forest Drive
Suite A-1, The Woodlands, Texas 77381 for necessary repairs.

Detcon Inc., as manufacturer, warrants each new HRT Bridge PCA to be free from defects in material and
workmanship under intended normal use for a period of one year. The warranty period begins on the date of