beautypg.com

Figure 6 installation with 700 gas sensor, Figure 7 remote 700 gas sensor with profi-ram – Detcon 700 Series Remote Sensor/Alarm Relay Module With Profibus DP Interface User Manual

Page 8

background image

700 Profi-RAM

NOTE: If the 700 sensor and Profi-RAM are directly connected, it is not necessary to
install/use the transient protection module that is shipped with every 700 Gas Sensor.

detcon inc.

Sensor

detcon inc.

MODEL
XX-700

PGM1

ZERO

PGM2

SPAN

Model 700

Power Input

mA Output

Profibus Interface

Fault

Annunciator

Alarm 1
Annunciator

Alarm 2
Annunciator

Figure 6 Installation with 700 Gas Sensor


If remote sensor separation is required, the Profi-RAM will be separated from the 700 sensor. Remote
separation distances of up to 1000 feet are possible with the recommended cables.

NOTE: It is highly recommended to install the interconnecting cabling inside rigid metal
conduit to eliminate potential EMI and RFI interference.

detcon inc.

Sensor

detcon inc.

MODEL
XX-700

2.115"

PGM1

ZERO

PGM2

SPAN

2"

Model 700

Power Input

mA Output

Profibus

Interface

700 Profi-RAM

Module

Cabling to/from Remote

700 Series Sensor

Remote 700

Series Sensor

Transient Protection

Module in Detcon

standard J-Box

Figure 7 Remote 700 Gas Sensor with Profi-RAM


The recommended cables for remote sensor separation are Belden 8770 (18AWG three wire, Shielded cable)
for connection of power and mA signal return, and Belden 9841 for serial Modbus™ communications. Use
Belden 3079A for the Profibus communications.

NOTE 1: The yellow (reserved wire) does not need to be connected in the remote sensor
configuration.

NOTE 2: Both the 3 wire power/mA cable and the 2 wire Modbus™ serial communications
cable are required when remote wiring between the Profi-RAM and the 700 Gas Sensor.

Profibus RAM I.M.

Rev. 0.3

Page 4 of 14