beautypg.com

Figure 5 sensor assembly breakaway, Figure 6 functional block diagram, Figure 7 plug-in sensor need new picture – Detcon FP-100 User Manual

Page 7

background image

Model FP-100

FP-100 Instruction Manual

Rev. 0.0

Page 3 of 30

O-Ring

100 Series Bottom

Housing Assembly

Plug-in
Replaceable
Sensor

Interconnect

Wires

Housing Bottom

Locking Screw

Intelligent Transmitter Module (ITM)
Micro-processor controlled circuit

encapsulated in an Explosion proof
housing.

Magnetic

Programming

Switches

Splash Guard

D

E

TC
O

N

, IN
C

.

LEL

100 %

FP-100

3

4

" NPT Locking Nut

Figure 5 Sensor Assembly Breakaway

NOTE: All metal components are constructed from electro polished 316 Stainless Steel in
order to maximize corrosion resistance in harsh environments.


FP-100 Intelligent Transmitter Module

The Transmitter Module is a microprocessor-based package that can be attached to an explosion proof junction
box. Circuit functions include bridge drive circuitry, on-board power supply, microprocessor, magnetic
programming switches, and a linear 4-20mA DC output. Magnetic program switches located on either side of
the ITM are activated via a hand-held magnetic programming tool, allowing non-intrusive operator interface
with the Transmitter Module. Electrical classifications are Class I, Division 1, Groups A, B, C, and D.









Figure 6 Functional Block Diagram


Field Replaceable Plug-in Sensor

The Detcon family of catalytic bead gas sensors are field proven, plug-in sensors with over-sized gold-plated
connections that eliminate corrosion problems. The sensor can be accessed and replaced in the field easily by
releasing the locking screw and unthreading the Bottom Housing. Detcon’s family of catalytic bead sensors
have a long shelf life and are supported by an industry-leading warranty.

Figure 7 Plug-in Sensor

I/O

Circuit

Protection

RS-485 Port

Analog 4-20mA Out

Power In

RS-485

4-20mA

Power

Micro-

Processor

Bridge drive

circuit


Plug-In

Sensor