beautypg.com

Appendix, 1 specifications – Detcon FP-100 User Manual

Page 31

background image

Model FP-100

FP-100 Instruction Manual

Rev. 0.0

Page 27 of 30

8. Appendix

8.1 Specifications


System Specifications

Sensor Type:

Continuous diffusion/adsorption type
Matched-Pair Catalytic Bead type
Plug-in Replaceable Type


Sensor Life:

3-5 years typical


Measuring Ranges:

0-100% LEL


Accuracy/ Repeatability:

± 3% LEL in 0-50% LEL range, ± 5% LEL in 51-100% LEL range


Response Time:

T50 < 10 seconds, T90 < 30 seconds


Electrical Classification:

CSA and US (NRTL)
Class I, Division 1, Groups A, B, C, D


ATEX
Class I, Zone 1, Group IIB+H

2

Ex d IIB+H

2

, T4


Approvals:

C

CSA

US

, ATEX, CE Marking


Warranty:

Electronics

2

years

Plug

in

Sensor

2

years

Environmental Specifications

Operating Temperature:

-40°C to +75°C typical

Storage Temperature:

-35°C to +55°C typical

Operating Humidity:

0-100% RH non-condensing

Operating Pressure:

Ambient ± 10%

Electrical Specifications

Input

Voltage:

10-28

VDC


Power Consumption:

Normal operation = 37 mA (0.89 watts @ 24VDC);
Maximum = 56 mA (1.35 watts @ 24VDC)


RFI/EMI Protection:

Complies with EN61326


Analog Output:

Linear 4-20mA DC current

750

ohms

maximum

loop

load

@

24VDC

0 mA All Fault Diagnostics

4-20 mA 0-100% full-scale

22 mA Over-range condition