Product specification, Specification of external pump (optional) – Detcon SG1 User Manual
Page 4
3
Product Specification
Model
SG1-O2
SG1-CO
SG1-H2S
SG1-H2
SG1-SO2
O
2
CO
H
2
S
H
2
SO
2
Measured Gas
0~30%
0~500ppm
0~1,000ppm
0~100ppm
0~200ppm
0~20ppm
0~100ppm
0~20ppm
0~100ppm
Measurement
Method
Electrochemical Type
Principle of
Measurement
Diffusion Type
Monitor
Custom-made Digital LCD
Alarm
90dB
Alert Lamp
Red LED
Vibration Alert
Vibration Alarm
Power Source
CR2
Applicable
Temperature &
Humidity
-20°C ~ +50°C, : 10% ~ 95% RH (non-condensing)
Explosion-Proof
EEx ia IIC T4 / IP67
Case
Rubber PC Case
Standard
Accessories
Belt Clip, Calibration Cap
Optional
Accessories
Small-Sized Pump for Sampling
Exterior
Dimension: 54mm(W) x 91mm(H) x 32 mm(D)
Weight: 120g (Including )
Specification of External Pump (Optional)
Power Source
AA Size Alkaline Battery, 1 ea
Continuous
Operation Time
Available to Operate for 5 hours or longer
Applicable
Temperature &
Humidity
-20°C ~ + 50°C, 0 to 95% RH
Exterior
Dimension: 34mm(W) x 270mm(H) x 47 mm(D)
Weight: 200g (Including )
Sampling Flux
0.5 liter / minute
Diagnosis Function
Deadlock Alarm, Alert of Insufficient (Red LED Display)