beautypg.com

Taking a reading testing baled hay, Testing in the windrow – Delmhorst Instrument F-2000 User Manual

Page 8

background image

TAKING A READING

Testing Baled Hay

h

Connect the bale prod to the connector on the top of the

meter.

h

Insert the bale prod into the bale.

h

Press the read key

!

The meter displays the %MC for

two seconds.

Notes

hThe bale prod is electrically insulated, except at the metal

points near the tip. The moisture content measured repre-
sents the hay in contact with the tip of the prod only.

hPartially cured hay may have wide variations in moisture

content throughout the bale. Readings should be taken in
several different parts of the bale and the highest readings
used as a guideline. The arrangement and compaction of
hay fibers in a bale may have an effect on meter readings.

hIf you are testing high density bales, we recommend using

the H-4 handle with the 830-2 10” prod, 830-3 18” prod,
or the 830-4 36” prod. Using the handle/prod combina-
tion eliminates stress on the instrument case that may
occur when trying to insert the prod into a high density or
large bale.

hWhen using the 36” prod, be sure to guide the prod into

the bale with one hand while pushing on the H-4 handle.

Testing in the Windrow

There are three ways to test moisture content in the windrow:

6

F-2000 owners manualB&W_F-2000 owners manual out 1/11/13 11:31 AM Page 8