Ef g, Connection basic operation, Remark – Additel 912 Low Pressure Test Pump User Manual User Manual

Page 2: Vent, Pre-pressure, Increasing pressure, Repeat pressurizing, Decreasing pressure, Vacuum preparation, Increasing vacuum pressure

background image

A

SW V mA COM 24V

SW V mA COM 24V

Connection

Basic Operation

dial gauge

pressure switch

pressure transmitter

flexible hose

M

0

0

0

0

0

open

B

DIGITAL PRESSURE CALIBRATOR

Units

A

0

25

50

75

100

k

open

M

0

0

0

0

0

C

DIGITAL PRESSURE CALIBRA

TOR

Units

A

0

25

50

75

100

set it to the mid

position of its travel

open

5

2

push the security bolt pin in

close

(

)

Do not over-tight

D

k

set it to the suitable

position

3

M

0

0

0

0

0

DIGITAL PRESSURE CALIBRA

TOR

Units

A

0

25

50

75

100

k

close

2

operate it to approach

desired pressure

fine adjust

4

Vent

Zeroing should be operated
under this condition only

.

Pre-pressure

Increasing pressure

main adjust

3

DIGITAL PRESSURE CALIBRA

TOR

Units

A

0

25

50

75

100

k

M

0

0

0

0

0

E

F

G

2

1

open it slowly to approach

the desired value, and close!

DIGITAL PRESSURE CALIBRA

TOR

Units

A

0

25

50

75

100

k

1 pull out

2

push in, select the

vacuum mode

5

DIGITAL PRESSURE CALIBRA

TOR

Units

A

0

25

50

75

100

k

0

0.02

0.04

0.06

0 08

.

0 08

.

- 0.1

MPa

M

0

0

0

0

0

① open

operate it to approach

desired pressure

3

close

set it to the

suitable position

3

4

Repeat pressurizing

fine adjust

5

main adjust

4

Decreasing pressure

main adjust

2

fine adjust

3

Vacuum preparation

Vent firstly.

set it to the mid

position of its travel

close

(but it must be open

switching the P/V selector)

H

0

0.02

0.04

0.06

0 08

.

0 08

.

- 0.1

DIGITAL PRESSURE CALIBRA

TOR

Units

A

0

25

50

75

100

k

close

1

operate it to approach

the desired value

J

0

0.02

0.04

0.06

0 08

.

0 08

.

- 0.1

DIGITAL PRESSURE CALIBRA

TOR

Units

A

0

25

50

75

100

k

1

2

I

DIGITAL PRESSURE CALIBRA

TOR

Units

A

0

25

50

75

100

k

2

① open

3 close

0

0.02

0.04

0.06

0 08

.

0 08

.

- 0.1

a

Increasing vacuum pressure

main adjust

3

fine adjust

4

Remark:

A Additel has made a concerted effort to provide complete and current information for the proper use of the equipment. The product

specifications and other information contained this manual are subject to change without notice.

B

:

: Above pictures are just for reference.

main adjust

4

fine adjust

5

operate it to approach

the desired value

Repeat vacuum pressure

Decreasing vacuum pressures

main adjust

2

fine adjust

3

open it slowly to approach

the desired value, and close!

k

Pressure Gauge

Pressure Gauge

Pressure Gauge

Vacuum Gauge

Pressure Gauge

Pressure Gauge

Pressure Gauge

Pressure Gauge

Pressure Gauge

Pressure Gauge

Vacuum Gauge

Vacuum Gauge

Vacuum Gauge

Vacuum Gauge

DIGITAL PRESSURE

CALIBRATOR

Units

A

0

25

50

75

100

k