beautypg.com

Electrical controls, Plc outputs plc inputs, Sensor wiring – Wellsaw 1316S User Manual

Page 31: Aux outputs

background image

31

COM 0

0

Q0.0

1

Q0.1

2

Q0.2

3

Q0.3

COM 1

4

Q0.4

5

Q0.5

6

Q0.6

30

31

38

33

34

35

36

7

Q0.7

37

COM 2

8

Q0.8

32

COM 3

8

9

Q0.9

9

38

1-SOL

2-SOL

B

A

3-SOL

4-SOL

B

A

5-SOL

6-SOL

A

B

7-SOL

8-SOL

A

B

4

4

CUTTING HEAD RAISE

CARRIAGE HIGH SPEED

BARFEED CARRIAGE RETURN

SAW VISE OPEN

SAW VISE CLOSE

CARRIAGE VISE OPEN

CARRIAGE VISE CLOSE

BARFEED RETURN ENABLE

SAW BLADE START

1

PLC OUTPUTS

PLC INPUTS

{

{

0

1

2

3

4

5

6

7

8

9

10

11

12

13

SENSOR

INPUTS

IO.0

IO.1

IO.2

IO.3

IO.4

IO.5

IO.6

IO.7

IO.8

IO.9

IO.10

IO.11

IO.12

IO.13

BARFEED

SENSOR

2M

1M

1-LS

1-PROX

BLACK

51 BLUE

3-LS

DL1

1 PS

DL2

R1C

R1A

MCR

50

50

50

10

11

12

13

14

15

16

17

18

19

20

21

22

23

HYDRAULIC MOTOR

BLADE MOTOR

CUTTING HEAD IS RAISED

CUTTING HEAD IS LOWERED

OUT OF STOCK

LEFT DOOR SWITCH

RIGHT DOOR SWITCH

A.C. DRIVE FAULT

MCR ON

SENSOR WIRING

1

2

3

4

1

2

3

4

9

2

1

9

3

8

1

2

3

4

1

2

3

4

9

2

1

9

3

8

50

50

10

51

BLUE

(IO.0)

11

(IO.1)

51

BARFEED

(CARRIAGE)

SENSOR

0V

5V

A

B

GROUND (BARE WIRE)

GREEN

GREEN

BLUE

53

52

WHITE

BLACK

52

53

TO 5V POWER SUPPLY

TERM

COM 0

0

1

2

3

Q1.0

Q1.1

Q1.2

Q1.3

4

5

6

7

COM 1

40

9-SOL

47

2 M

42

2A

5

FU8

24VDC

45

A.C. DRIVE

46

60

2 O/L

3CR

3 O/L

L13

L13

+24

AUX OUTPUTS

4

CUTTING HEAD LOWER

HYDRAULIC PUMP

COOLANT PUMP

OPTIONAL CHIP AUGER

MCR START ENABLE

44

1 O/L

4

7

1M

8

9

Q1.4

OPTIONAL ELECTRICAL
DOOR INTERLOCK

ON

AUTO

62

SL 1

MOTION DETECTOR
PROXIMITY SWITCH

SYSTEM AIR
PRESSURE SWITCH

BARFEED
CARRIAGE FORWARD

Electrical Controls

Electrical Controls