Electrical controls main panel, 1m 2ma 2m, A/c drive – Wellsaw 1316S User Manual
Page 26: Lci-d09, V nc +v, Fu 4, Fuses

26
208/230
H1 H3 H2 H4
460
30
A
Disconnect
FU 1
FU 2
FU 3
1L
1L
1L
1
2
3
BLACK 12 GA.
BLACK 12 GA.
RED #9
BLUE #50
RED #47
RED #9
BLUE #60
BLUE #50
BLUE #13
BLUE #60
WHITE #1
RED #47
BLUE #50
1L
1L
1L
1L
RED
#4
BLACK 12 GA.
BLACK 12 GA.
BLACK 12 GA.
1L
1L
1
2
3
LCI-D09
LCI-D09
LCI-D09
1M
2MA
2M
BLUE #12
14 NO
22 NC
A2
1T3
1T2
1T1
T1
T2
T3
RESET
ST
OP
LRD 08
BLACK
12 GA.
97 NO
98 NO
95 NC
96 NC
BLACK
12 GA.
BLACK
12 GA.
RED
2T1
2T2
2T3
T1
T2
T3
WHITE #1
A/C DRIVE
BLACK 12 GA.
BLACK 12 GA.
BLACK 12 GA.
BLUE #50
BLUE #13
BLUE #12
BLUE
BLUE
BLUE
BLUE
BLUE
BLUE
BLUE
BLUE
BLUE
BLUE
BLUE
#10
#11
BLUE #23
BLUE #21
#22
DC
IN
COM
RELA
Y
OUT
AUX.
RED
BLUE #52
#40
GREEN ON - V
BLUE #53
BLUE #52
BLUE #53
RED #9
BLUE #50
WHITE 12 GA.
BLACK 12 GA.
H4
H2
H3
H1
X1
XF
X2
GREEN
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0V
+24V
#51
#50
T1
T2
T3
T1
T2
T3
WHITE #1
14 NO
22 NC
A2
L3
L2
L1
L3
L2
L1
L3
L2
L1
A2
22 NC
14 NO
A1
23 NC
13 NO
A1
23 NC
13 NO
A1
23 NC
13 NO
#19
#18
#17
#16
#15
#14
4
14
5
24
6
34
RED #3
NOTE:
1) ALL WIRE TO BE MTW
2) BLACK, WHITE, GREEN WIRE TO BE 12 GA.
3) GROUND LEADS CAN BE 16 GA. IF RUN
DIRECTLY TO PANEL.
4) ALL GROUND LUGS TO BE CLOSED LOOP
WIRE ENDS.
5) RED, BLUE CONTROL WIRING TO BE 16 GA.
-V NC +V
RED #3
BLUE #23
WHITE #1
2T3
2T2
2T1
H1 H3 H2 H4
FUSES
NUMBER
FU 1
FU 2
FU 3
FU 4
FU 5
FU 8
DESCRIPTION
DISCONNECT LEG 1
DISCONNECT LEG 2
DISCONNECT LEG 3
TRANSFORMER
WORKLIGHT
COOLANT PUMP
AMP
15
15
15
5
1
3
FU 4
Electrical Controls Main Panel
Electrical Controls Main Panel