A/C DRIVE

ALTIVAR 31 SET UP:

1: CTL - rfc = Fr2

2: CTL - LAC = L2

3: drc - bfr = 60

- un5 = 230 (or acutal motor voltage)

- tfr = 120

4: CTL - Fr2 = Updt

5: SET - LSP = 15

- HSP = 120

6: Fun - Upd - USP = L13 (+) speed input

- dsp = L14 (+) speed input

- Str = EEP (stores information)