Distance measurement
■
■
Range with Nikon specified prisms
(Good conditions
2
)
- With reflector sheet (5 cm x 5 cm):
Nivo 1.C, Nivo 2.C: 1.5 m to 270 m
Nivo 3.C, Nivo 5.C: 1.5 m to 300 m
- With single prism 6.25 cm Nivo 1.C,
Nivo 2.C: 1.5 m to 3,000 m Nivo 3.C,
Nivo 5.C: 1.5 m to 5,000 m
■
■
Range reflectorless mode
1
- Nivo 1.C, Nivo 2.C
KGC (18%)
1
Good
2
: 350 m (1,148 feet)
Normal
3
: 350 m (1,148 feet)
Difficult
4
: 200 m (650 feet)
KGC (90%)
1
Good
2
: 500 m (1,640 feet)
Normal
3
: 400 m (1,312 feet)
Difficult
4
: 250 m (820 feet)
- Nivo 3.C, Nivo 5.
KGC (18%)
1
Good
2
: 280 m (820 feet)
Normal
3
: 250 m (820 feet)
Difficult
4
: 200 m (650 feet)
KGC (90%)
1
Good
2
: 500 m (1,640 feet)
Normal
3
: 500 m (1,640 feet)
Difficult
4
: 300 m (984 feet)
- Shortest possible range: 1.5 m
(4 feet 11 1⁄16 inches)
■
■
Accuracy
5
(Precise mode) ISO 17123-4
- Prism: ±(2+2 ppm × D) mm
- Reflectorless: (3+2 ppm × D) mm
■
■
Measuring interval
6
- Nivo 1.C, Nivo 2.C
Prism mode
Precise mode: 1.6 s
Normal mode: 0.8 s
Reflectorless mode
7
Precise mode: 2.1 s
Normal mode: 1.2 s
- Nivo 3.C, Nivo 5.C
Prism mode
Precise mode: 1.5 s
Normal mode: 0.8 s
Reflectorless mode
7
Precise mode: 1.8 s
Normal mode: 1.0 s
- Least count: 1 mm 10 mm
Angle Measurement
■
■
ISO 17123-3 Accuracy (horizontal and
vertical): 1”/0.3 mgon Nivo 1.C 2”/0.6 mgon
Nivo 2.C; 3”/1 mgon Nivo 3.C; 5”/1.5 mgon
Nivo 5.C
■
■
Reading system: Absolute encoder
■
■
Circle diameter: 62 mm (2.4 in)
■
■
Horizontal/Vertical angle: Diametrical
■
■
Minimum increment
- Nivo 1.C: Degree: 0.5”; Gon: 0.1 mgon
- Nivo 2.C, Nivo 3.C, Nivo 5.C: Degree: 1”;
Gon: 0.1 mgon
Telescope
■
■
Tube length: 125 mm (4.9 in)
■
■
Image: Erect
■
■
Magnification: 30×
(18x/36x with optional eyepieces)
■
■
Effective diameter of objective:
- Nivo 1.C, Nivo 2.C: 40 mm (1.6 in)
- Nivo 3.C, Nivo 5.C: 45 mm (1.7 in)
■
■
EDM diameter:
- Nivo 1.C, Nivo 2.C: 45 mm (1.7 in)
- Nivo 3.C, Nivo 5.C: 50 mm (1.9 in)
■
■
Field of view: 1°20’
■
■
Resolving power: 3”
■
■
Minimum focusing distance: 1.5 m
(4 feet 11 1⁄16 inches)
■
■
Laser Pointer: Coaxial Red Light
General Specifications
■
■
Level vials
- Sensitivity of circular level vial: 10’/2 mm
■
■
Optical plummet
- Image: Erect
- Magnification: 3×
- Field of view: 5°
- Focusing range: 0.5 m to ∞
■
■
Display:
- Left display face: QVGA, 16 bit color, TFT
LCD, backlit (320x240 pixel)
- Right display face: Backlit, graphic LCD
(128x64 pixel)
■
■
Laser plummet (optional): 4 levels
■
■
Memory: 128 MB RAM, 128MB Flash memory
■
■
Processor: Marvell PXA300 XScale 624 MHz
■
■
Dimensions (W x D x H):
149 mm x 145 mm x 306 mm
(5.8 in x 5.7 in x 12.0 in)
■
■
Weight (approx.)
- Nivo 1.C, Nivo 2.C Main unit
(without batteries): 3.9 kg (8.6 lb)
- Nivo 3.C, Nivo 5.C Main Unit
(without batteries): 3.8 kg (8.4 lb)
- Battery: 0.1 kg (0.2 lb)
- Carrying case: 2.3 kg (5.1 lb)
Power
■
■
Internal Li-ion battery (x2)
■
■
Output voltage: 3.8 V DC
■
■
Operating time
8
- Nivo 1.C, Nivo 2.C
approx. 12 hours
(continuous distance/angle measurement)
approx. 26 hours
(distance/angle measurement every 30 s)
approx. 28 hours
(continuous angle measurement)
- Nivo 3.C, Nivo 5.C
approx. 7.5 hours
(continuous distance/angle measurement)
approx. 16 hours
(distance/angle measurement every 30 s)
approx. 20 hours
(continuous angle measurement)
■
■
Charging time: Full charge - 4 hours
Tilt Sensor
■
■
Type: Dual-axis
■
■
Method: Liquid-electric detection
■
■
Compensation range: ±3.5’
Communications
■
■
Communication ports: 1 x serial
(RS-232C), 2 x USB (host and client)
■
■
Wireless communications:
Integrated Bluetooth
Environmental Conditions
■
■
Operating temperature range:
–20 °C to +50 °C
■
■
Storage temperature:
–25 °C to +60° C
■
■
Atmospheric correction
- Temperature range: –40 °C to +60 °C
- Barometric pressure: 400 mmHg to 999
mmHg/533 hPa to 1,332 hPa/15.8 inHg
to 39.3 inHg
■
■
Dust and water protection:
IP66 (Nivo1.C IP56)
Certification
■
■
Class B Part 15 FCC certification,
CE Mark approval. C-Tick.
■
■
Laser safety IEC 60825-1 am2:2007
■
■
Prism mode: Class 1 laser
■
■
Laser plummet (optional): Class 2 laser
■
■
Nivo 1.C ,Nivo 2.C Reflectorless / Laser
Pointer: Class 3R laser
■
■
Nivo 3.C, Nivo 5.C Reflectorless / Class 1 laser
■
■
Nivo 3.C, Nivo 5.C Laser Pointer: Class 2 laser
(1)
Measuring distance may vary depending on targets and
measuring conditions.
(2)
Good conditions (good visibility, overcast, twilight,
underground, low ambient light).
(3)
Normal conditions (normal visibility, object in the shadow,
moderate ambient light).
(4)
Difficult conditions (haze, object in direct sunlight, high
ambient light).
(5) ±(3+3 ppm × D) mm –20 °C to –10 °C, +40 °C to +50 °C
(6)
Measuring time may vary depending on measuring distance
and conditions. For the initial measurement, it may take a
few more seconds.
(7) Battery life specification at 25 °C. Operation time may be shorter
in low temperatures or if the battery is not new.
(8)
Kodak Gray Card, Catalog number E1527795.
Specifications are subject to change without prior notice.
Bluetooth type approvals are country specific.
Nivo C Series Total Station
©2014 Trimble Navigation Limited. All rights reserved. Nikon is a registered trademark of Nikon Corporation. All other trademarks are the property of their respective owners.
www.spectraprecision.com
Contact Information:
AMERICAS
Spectra Precision Division
10368 Westmoor Drive
Westminster, CO 80021, USA
+1-720-587-4700 Phone
888-477-7516 (Toll Free in USA)
EUROPE, MIDDLE EAST AND AFRICA
Spectra Precision Division
Rue Thomas Edison
ZAC de la Fleuriaye - CS 60433
44474 Carquefou (Nantes), France
+33 (0)2 28 09 38 00 Phone
ASIA-PACIFIC
Spectra Precision Division
80 Marine Parade Road
#22-06, Parkway Parade
Singapore 449269, Singapore
+65-6348-2212 Phone