Model M05 Metallic Page 31

DUAl PORTING OPTIONS

Several dual porting options are

possible. The pump can be converted

to a dual port arrangement on both

the suction and the discharge ends.

The porting can be configured to a

single suction and a dual discharge.

The porting can be changed to a dual

suction and a single discharge.

The above changes are possible

because the porting flange of the

elbows (items 19) are designed to mate

with 1/2" NPT or BSP (Tapered)

connection.

DUAl PORTING OF BOTH SUCTION

AND DISCHARGE ENDS OF THE

PUMP

Converting the pump from the

standard single suction and discharge

porting configuration to dual porting at

each end is easy. Simply remove the

manifold seals and manifolds (items 24

and 29 from pump assembly drawing)

from the pump.

The discharge elbows and suction

elbows can be rotated 90° increments

(see arrows and optional positioning in

the Dual Port Options Drawing.)

SINGlE PORTING OF THE SUCTION

AND DUAl PORTING OF THE PUMP

DISCHARGE

To convert the pump from the

standard single suction and single

discharge porting configuration to a dual

discharge porting arrangement remove

the only the discharge manifolds and

manifold seals. Position the discharge

elbows in the desired direction at 90°

increments. (See arrows and optional

positioning in the Dual Porting Drawing.)

DUAl PORTING OF THE SUCTION

AND SINGlE PORTING OF THE

PUMP DISCHARGE

To convert the pump from the

standard single suction and single

discharge porting configuration to a dual

suction porting arrangement remove the

only the suction (bottom) manifolds and

manifold seals.

Position the suction elbows in the

desired direction at 90° increments.

(See arrows and optional positioning

in the Dual Porting Drawing.)

NOTE: See Repair Parts lists on next page.

Read these instructions

completely, before in-

stallation and start-up.

It is the responsibility of

the purchaser to retain

this manual for reference. Failure to

comply with the recommendations stated

in this manual will damage the pump, and

void factory warranty.

IMPORTANT