SANDPIPER M05 Metallic User Manual
Page 33
m05mdl1sm-rev0711
Model M05 Metallic Page 31
DUAl PORTING OPTIONS
Several dual porting options are
possible. The pump can be converted
to a dual port arrangement on both
the suction and the discharge ends.
The porting can be configured to a
single suction and a dual discharge.
The porting can be changed to a dual
suction and a single discharge.
The above changes are possible
because the porting flange of the
elbows (items 19) are designed to mate
with 1/2" NPT or BSP (Tapered)
connection.
DUAl PORTING OF BOTH SUCTION
AND DISCHARGE ENDS OF THE
PUMP
Converting the pump from the
standard single suction and discharge
porting configuration to dual porting at
each end is easy. Simply remove the
manifold seals and manifolds (items 24
and 29 from pump assembly drawing)
from the pump.
The discharge elbows and suction
elbows can be rotated 90° increments
(see arrows and optional positioning in
the Dual Port Options Drawing.)
SINGlE PORTING OF THE SUCTION
AND DUAl PORTING OF THE PUMP
DISCHARGE
To convert the pump from the
standard single suction and single
discharge porting configuration to a dual
discharge porting arrangement remove
the only the discharge manifolds and
manifold seals. Position the discharge
elbows in the desired direction at 90°
increments. (See arrows and optional
positioning in the Dual Porting Drawing.)
DUAl PORTING OF THE SUCTION
AND SINGlE PORTING OF THE
PUMP DISCHARGE
To convert the pump from the
standard single suction and single
discharge porting configuration to a dual
suction porting arrangement remove the
only the suction (bottom) manifolds and
manifold seals.
Position the suction elbows in the
desired direction at 90° increments.
(See arrows and optional positioning
in the Dual Porting Drawing.)
NOTE: See Repair Parts lists on next page.
Read these instructions
completely, before in-
stallation and start-up.
It is the responsibility of
the purchaser to retain
this manual for reference. Failure to
comply with the recommendations stated
in this manual will damage the pump, and
void factory warranty.
IMPORTANT