beautypg.com

SANDPIPER M05 Metallic User Manual

Page 10

background image

m05mdl1sm-rev0711

Model M05 Metallic Page 8

PRINCIPlE OF PUMP OPERATION

This ball type check valve pump

is powered by compressed air and is

a 1:1 ratio design. The inner side of

one diaphragm chamber is alternately

pressurized while simultaneously

exhausting the other inner chamber.

This causes the diaphragms, which

are connected by a common rod

secured by plates to the centers of the

diaphragms, to move in a reciprocating

action. (As one diaphragm performs the

discharge stroke the other diaphragm is

pulled to perform the suction stroke in

the opposite chamber.) Air pressure is

applied over the entire inner surface of

the diaphragm while liquid is discharged

from the opposite side of the diaphragm.

The diaphragm operates in a balanced

condition during the discharge stroke

which allows the pump to be operated

at discharge heads over 200 feet (61

meters) of water.

For maximum diaphragm life, keep

the pump as close to the liquid being

pumped as possible. Positive suction

head in excess of 10 feet of liquid

(3.048 meters) may require a back

pressure regulating device to maximize

diaphragm life.

Alternate pressurizing and

exhausting of the diaphragm chamber

is performed by an externally mounted,

pilot operated, four way spool type

air distribution valve. When the spool

shifts to one end of the valve body, inlet

pressure is applied to one diaphragm

chamber and the other diaphragm

chamber exhausts. When the spool

shifts to the opposite end of the valve

body, the pressure to the chambers

is reversed. The air distribution valve

spool is moved by a internal pilot valve

which alternately pressurizes one end

of the air distribution valve spool while

exhausting the other end. The pilot valve

is shifted at each end of the diaphragm

stroke when a actuator plunger is

contacted by the diaphragm plate. This

actuator plunger then pushes the end

of the pilot valve spool into position to

activate the air distribution valve.

The chambers are connected with

manifolds with a suction and discharge

check valve for each chamber,

maintaining flow in one direction

through the pump.
INSTAllATION AND START-UP

Locate the pump as close to the

product being pumped as possible.

Keep the suction line length and

number of fittings to a minimum. Do not

reduce the suction line diameter.

For installations of rigid piping,

short sections of flexible hose should

be installed between the pump and

the piping. The flexible hose reduces

vibration and strain to the pumping

system. A DA05 Surge Dampener

is recommended to further reduce

pulsation in flow.
AIR SUPPlY

Air supply pressure cannot exceed

125 psi (8.6 bar). Connect the pump

air inlet to an air supply of sufficient

capacity and pressure required for

desired performance. When the air

supply line is solid piping, use a short

length of flexible hose not less than

1/2" (13mm) in diameter between

the pump and the piping to reduce

strain to the piping. The weight of the

air supply line, regulators and filters

must be supported by some means

other than the air inlet cap. Failure to

provide support for the piping may result

in damage to the pump. A pressure

regulating valve should be installed

to insure air supply pressure does not

exceed recommended limits.
AIR VAlVE lUBRICATION

The air distribution valve and the

pilot valve are designed to operate

WITHOUT lubrication. This is the

preferred mode of operation. There may

be instances of personal preference

or poor quality air supplies when

lubrication of the compressed air

supply is required. The pump air system

will operate with properly lubricated

compressed air supply. Proper

lubrication requires the use of an air line

lubricator (available from MARATHON)

set to deliver one drop of SAE 10 non-

detergent oil for every 20 SCFM (9.4

liters/sec.) of air the pump consumes

at the point of operation. Consult the

pump’s published Performance Curve

to determine this.
AIR lINE MOISTURE

Water in the compressed air supply

can create problems such as icing or

freezing of the exhaust air, causing

the pump to cycle erratically or stop

operating. Water in the air supply can

be reduced by using a point-of-use

air dryer to supplement the user’s air

drying equipment. This device removes

water from the compressed air supply

and alleviates the icing or freezing

problems.

AIR INlET AND PRIMING

To start the pump, open the air valve

approximately 1/2" to 3/4" turn. After

the pump primes, the air valve can be

opened to increase air flow as desired.

If opening the valve increases cycling

rate, but does not increase the rate of

flow, cavitation has occurred. The valve

should be closed slightly to obtain the

most efficient air flow to pump flow ratio.
BETWEEN USES

When the pump is used for materials

that tend to settle out or solidify when

not in motion, the pump should be

flushed after each use to prevent

damage. (Product remaining in the

pump between uses could dry out or

settle out. This could cause problems

with the diaphragms and check valves

at restart.) In freezing temperatures

the pump must be completely drained

between uses in all cases.