Solenoid shifted air valve drawing, Optional – SANDPIPER S05 User Manual
Page 19
![background image](/manuals/364239/19/background.png)
s05nmdl2sm-rev0614
sandpiperpump
.
com
Model S05 Non-Metallic •
16
Solenoid Shifted Air Valve Drawing
*Special Conditions For Safe Use
A fuse corresponding to its rated current (max. 3*I
rat
according IEC 60127.2.1) or a
motor protecting switch with short-circuit and thermal instantaneous tripping (set to
rated current) shall be connected in series to each solenoid as short circuit protection.
For very low rated currents of the solenoid the fuse of lowest current value according
to the indicated IEC standard will be sufficient. The fuse may be accommodated in the
associated supply unit or shall be separately arranged. The rated voltage to the fuse
shall be equal to or greater than the stated rated voltage of the magnet coil. The
breakage capacity of the fuse-link shall be as high as or higher than the maximum
expected short circuit current at the location of the installation (usually 1500 A). A
maximum permissible ripple of 20% is valid for all magnets of direct-current design.
SOLENOID SHIFTED AIR VALVE PARTS LIST
(Includes all items used on Composite Repair Parts List except as shown)
Item
Part Number
Description
Qty
4
114.023.551
Bracket, Intermediate
1
38
893.099.000
Solenoid Valve, NEMA4
1
39
219.001.000
Solenoid Coil, 24VDC
1
219.004.000
Solenoid Coil, 24VAC/12VDC
1
219.002.000
Solenoid Coil, 120VAC
1
219.003.000
Solenoid Coil, 240VAC
1
40
241.001.000
Connector, conduit
1
241.003.000
Conduit Connector with
1
Suppression Diode (DC Only)
41
171.065.115
Capscrew, Flanged 1/4.20 x 1.00
4
42
618.050.150
Plug (Replaces Item 7)
2
IEC EEX m T4
For Explosion Proof Solenoid Coils used in North America and
outside the European Union.
39
219.009.001
Solenoid Coil, 120VAC 60 H
z
1
219.009.002
Solenoid Coil, 240VAC 60 H
z
1
219.009.003
Solenoid Coil, 12VDC
1
219.009.004
Solenoid Coil, 24VDC
1
219.009.005
Solenoid Coil, 110VAC 50 H
z
1
219.009.006
Solenoid Coil, 230VAC 50 H
z
1
Item 40 (Conduit Connector) is not required
For ATEX Compliant Solenoid Coils used in the European Union
39 219.011.001
Solenoid Coil, Single mounting 12 VDC, 3.3W / 267mA
1
219.011.002
Solenoid Coil, Single mounting 24 VDC, 3.3W / 136mA
1
219.011.003
Solenoid Coil, Single mounting 110/120 VAC, 3.4W / 29mA 1
219.011.004
Solenoid Coil, Single mounting 220/240 VAC, 3.4W / 15mA 1
Note: Item 40 (Conduit Connector) is not required
*
Compressed Air Temperature Range: Maximum Ambient
Temperature to plus 50°C
SOLENOID SHIFTED OPERATION
The Solenoid Shifted pump has a solenoid operated, air distribution valve in
place of the standard pilot operated, air distribution valve. Where a pilot valve
is normally utilized to cycle the pump’s air distribution valve, an electric solenoid
is utilized. The solenoid coil is connected to a customer-supplied control. As the
solenoid is powered, one of the pump’s air chambers is pressurized while the
other chamber is exhausted. When electric power is turned off, the solenoid
shifts and the pressurized chamber is exhausted while the other chamber
is pressurized. By alternately applying and removing power to the solenoid,
the pump cycles much like a standard pump, with one exception. This option
provides a way to precisely control and monitor pump speed.
BEFORE INSTALLATION
BEFORE WIRING THE SOLENOID, make certain it is compatible with your
system voltage.
41
8
20
26
42
30
26
42
30
4
22
38
12
39
40
#2 Terminal
Neutral
(Negative)
#1 Terminal
Power
(Positive)
3rd Terminal
for ground.
Wiring
Diagram
II 2G EEx m c T5
II 2D c IP65 T100°C
II 2G EEx m c II T5
II 3/2 2G EEx m c II T5
II 2D c IP65 T100°C
6: OPTIONAL