16

Solenoid Shifted Air Valve Drawing

*Special Conditions For Safe Use

A fuse corresponding to its rated current (max. 3*I

rat

according IEC 60127.2.1) or a

motor protecting switch with short-circuit and thermal instantaneous tripping (set to

rated current) shall be connected in series to each solenoid as short circuit protection.

For very low rated currents of the solenoid the fuse of lowest current value according

to the indicated IEC standard will be sufficient. The fuse may be accommodated in the

associated supply unit or shall be separately arranged. The rated voltage to the fuse

shall be equal to or greater than the stated rated voltage of the magnet coil. The

breakage capacity of the fuse-link shall be as high as or higher than the maximum

expected short circuit current at the location of the installation (usually 1500 A). A

maximum permissible ripple of 20% is valid for all magnets of direct-current design.

SOLENOID SHIFTED AIR VALVE PARTS LIST

(Includes all items used on Composite Repair Parts List except as shown)

Item

Part Number

Description

Qty

4

114.023.551

Bracket, Intermediate

1

38

893.099.000

Solenoid Valve, NEMA4

1

39

219.001.000

Solenoid Coil, 24VDC

1

219.004.000

Solenoid Coil, 24VAC/12VDC

1

219.002.000

Solenoid Coil, 120VAC

1

219.003.000

Solenoid Coil, 240VAC

1

40

241.001.000

Connector, conduit

1

241.003.000

Conduit Connector with

1

Suppression Diode (DC Only)

41

171.065.115

Capscrew, Flanged 1/4.20 x 1.00

4

42

618.050.150

Plug (Replaces Item 7)

2

IEC EEX m T4

For Explosion Proof Solenoid Coils used in North America and

outside the European Union.

39

219.009.001

Solenoid Coil, 120VAC 60 H

z

1

219.009.002

Solenoid Coil, 240VAC 60 H

z

1

219.009.003

Solenoid Coil, 12VDC

1

219.009.004

Solenoid Coil, 24VDC

1

219.009.005

Solenoid Coil, 110VAC 50 H

z

1

219.009.006

Solenoid Coil, 230VAC 50 H

z

1

Item 40 (Conduit Connector) is not required

For ATEX Compliant Solenoid Coils used in the European Union

39 219.011.001

Solenoid Coil, Single mounting 12 VDC, 3.3W / 267mA

1

219.011.002

Solenoid Coil, Single mounting 24 VDC, 3.3W / 136mA

1

219.011.003

Solenoid Coil, Single mounting 110/120 VAC, 3.4W / 29mA 1

219.011.004

Solenoid Coil, Single mounting 220/240 VAC, 3.4W / 15mA 1

Note: Item 40 (Conduit Connector) is not required

*

Compressed Air Temperature Range: Maximum Ambient

Temperature to plus 50°C

SOLENOID SHIFTED OPERATION

The Solenoid Shifted pump has a solenoid operated, air distribution valve in

place of the standard pilot operated, air distribution valve. Where a pilot valve

is normally utilized to cycle the pump’s air distribution valve, an electric solenoid

is utilized. The solenoid coil is connected to a customer-supplied control. As the

solenoid is powered, one of the pump’s air chambers is pressurized while the

other chamber is exhausted. When electric power is turned off, the solenoid

shifts and the pressurized chamber is exhausted while the other chamber

is pressurized. By alternately applying and removing power to the solenoid,

the pump cycles much like a standard pump, with one exception. This option

provides a way to precisely control and monitor pump speed.

BEFORE INSTALLATION

BEFORE WIRING THE SOLENOID, make certain it is compatible with your

system voltage.

41

8

20

26

42

30

26

42

30

4

22

38

12

39

40

#2 Terminal

Neutral

(Negative)

#1 Terminal

Power

(Positive)

3rd Terminal

for ground.

Wiring

Diagram

II 2G EEx m c T5
II 2D c IP65 T100°C

II 2G EEx m c II T5

II 3/2 2G EEx m c II T5

II 2D c IP65 T100°C

6: OPTIONAL