beautypg.com

Installation, Caution – Lincoln Electric IM954 VANTAGE 500 DEUTZ User Manual

Page 17

background image

A-9

INSTALLATION

VANTAGE® 500 DEUTZ

A-9

CONNECTION OF THE LN-25 TO THE
VANTAGE® 500 DEUTZ

The LN-25 with or without an internal contactor may
be used with the VANTAGE® 500 DEUTZ. See the
appropriate connection diagram in the DIAGRAMS
section.

• Shut the welder off.

• For electrode Positive, connect the electrode cable

from the LN-25 to the “+” terminal of the welder and
work cable to the “-” terminal of the welder. For elec-
trode Negative, connect the electrode cable from the
LN-25 to the “-” terminal of the welder and work
cable to the “+” terminal of the welder.

• Attach the single lead from the front of the LN-25 to

work using the spring clip at the end of the lead. This
is a sense lead to supply current to the wire feeder
motor; it does not carry welding current.

• Set the SELECTOR switch to the “CV-WIRE” posi-

tion.

• Set the “WELDING TERMINALS” switch to “WELD

TERMINALS ON”

• Adjust the “ARC CONTROL” knob to desired crisp-

ness. Generally, welding is best if the “ARC CON-
TROL” is set to SOFT for MIG and CRISP for
INNERSHIELD. You may however, want to start in
the middle and adjust (as needed) from there.

• Set the “IDLE” switch to the “AUTO” position. When

not welding, the VANTAGE® 500 DEUTZ engine will
be at the low idle speed. If you are using an LN-25
with an internal contactor, the electrode is not ener-
gized until the gun trigger is closed.

If you are using an LN-25 without an internal con-
tactor, the electrode will be energized when the
VANTAGE® 500 DEUTZ is started.

------------------------------------------------------------------------

• When the gun trigger is closed, the current sensing

circuit will cause the wire to begin to feed and the
welding process is started.

CONNECTION OF AN NA-3 AUTOMATIC
WELDING SYSTEM TO THE VANTAGE®
500 DEUTZ

For connection diagrams and instructions for connect-
ing an NA-3 Welding System to the VANTAGE® 500
DEUTZ, refer to the NA-3 Welding System instruction
manual. The connection diagram for the LN-8 can be
used for connecting the NA-3.

• Set the Wire Feeder Voltage Switch to 115V.

CONNECTION OF MAGNUM SG SPOOL
GUN TO THE VANTAGE® 500 DEUTZ (SEE
SECTION F)

CAUTION