23. Display is blank

a. Power source is OFF.

b. Feeder supply fuse or circuit

breaker at power source is blown
or tripped.

c. Display or Control PC board is

bad

a. Turn ON power source.

b. Check input cable and feeder unit for

short in 41 and 42 circuit. Check for
shorted motor. Replace fuse or reset
circuit breaker.

c. Observe LED mounted on Control PC

board. It should blink on and off at a
controlled rate of 1 second ON and 1
second OFF. If so, then replace
Display PC board. If not, replace
Control PC board. (See Procedure
for Replacing PC boards)