beautypg.com

Maintenance, Component replacement procedures, Caution – Lincoln Electric IM790 SP-175 Plus User Manual

Page 26

background image

D-3

D-3

MAINTENANCE

COMPONENT REPLACEMENT
PROCEDURES

CHANGING THE CONTACT TIP

1. Unplug or turn power switch to Off

O

position.

2. Refer to Figure D.2. Remove the gas nozzle from

the gun by unscrewing counter-clockwise.

3. Remove the existing contact tip from the gun by

unscrewing counter-clockwise.

4. Insert and hand tighten desired contact tip.

5. Replace gas nozzle.

CHANGING THE SP-175 Plus FOR USE
WITH INNERSHIELD FLUX CORED WIRE

Change The Contact Tip

Acquire Innershield Welding Kit (See ACCES-
SORIES section). Note: Feeding .035

Innershield

requires nothing extra but feeding will be optimized
with the use of the KP666-035C drive roll.

1. Refer to Figure D.2. Remove the gas nozzle from

the gun by unscrewing counter-clockwise.

2. Remove the existing contact tip from the gun by

unscrewing counter-clockwise.

3. Insert and hand tighten the contact tip for use with

.035

or .045

(.045

requires a liner change also)

Innershield Flux Cored Wire.

4. Replace gas nozzle

The gasless nozzle may be

used instead of the gas nozzle to give improved
visibility of the arc.

CHANGING DRIVE ROLL

The drive roll, Figure D.1 Item 1, has two grooves; one
for .023"

.025" (0.6mm) solid steel electrode and a larg-

er groove for .030" (0.8mm) solid and .035" (0.9mm) flux-
cored steel electrode. As shipped, the drive roll is
installed in the .023"

.025" (0.6mm) position.

If .030"-.035" (0.9mm) wire is to be used, the drive roll
must be reversed as follows:

1. Turn the power switch to OFF (marked

O

).

2. Release the spring-loaded idle arm tensioner, Figure D.1

Item 2, and lift the idle roll arm, Figure D.1 Item 3, away
from the drive roll.

3. Loosen the Phillips Head screw holding the drive

roll onto the drive shaft.

When inching the welding wire, the drive rolls,
gun connector block, and gun contact tip are
energized relative to work and ground and remain
energized for several seconds after the gun trig-
ger is released.
------------------------------------------------------------------------

4. Remove the drive roll, flip over and reinstall with the

opposite groove closest to the gearbox.

NOTE: The stencil of the groove that you want to use

is marked on the outside of the drive roll
(when installed)

5. Push a length of straightened welding wire through

the wire feeder guide tubes and reset the Phillips
Head screw to secure the drive roll onto the shaft.

6. Reapply the spring loaded idle arm tensioner.

7. Turn the power

ON

(I) and check the drive roll for

slipping when feeding wire. DO NOT OVERTIGHTEN -

If necessary, tighten or loosen the spring loaded
idle arm tensioner (2).

FIGURE D.1

CAUTION

3

2

1

SP-175 PLUS