MAINTENANCE

SAFETY PRECAUTIONS

ELECTRIC SHOCK can kill.

Disconnect input power by remov-

ing plug from receptacle before
working inside SP-175 Plus . Use
only grounded receptacle. Do not
touch electrically

hot

parts

inside SP-175 Plus .

Have qualified personnel do the

maintenance and trouble shooting
work.

ITEMS REQUIRING NO
MAINTENANCE

Drive Motor and Gearbox

Lifetime lubrication

Fan Motor- Lifetime lubrication.

Wire Reel Spindle

Do NOT lubricate shaft.

ROUTINE AND PERIODIC MAINTE-
NANCE

BEFORE EACH USE

Check over machine and accessories for any obvious

condition that may prevent safe performance or oper-
ation, repair or replace items as necessary to correct
any abnormal condition.

AFTER 5 MINUTES OF WELDING
or when spatter accumulates in nozzle

Clean nozzle to avoid bridging between nozzle and

contact tip which results in shorted nozzle, poor welds
and overheated gun. Hint: Anti-stick spray or gel
available from a welding supply supplier may reduce
buildup and aid in spatter removal.

AFTER EACH SPOOL OF WIRE FEED

Remove contact tip and clean inside diameter with

short piece of wire

Clean cable liner

when rough and erratic wire feed-

ing occur.

MAINTENANCE

D-1

D-1

WARNING

AFTER FEEDING 50# OF FLUX CORED
WIRE OR 300# OF SOLID WIRE

Unplug machine or turn power switch to OFF

– “

O

position. Remove gun and cable from machine.

Remove gas nozzle and contact tip from gun.

Lay cable out straight - blow out gently into gun end

with compressed air. Bend cable back and forth

blow out again

Repeat until clean.

Excessive pressure at start may cause the dirt to
form a plug.

PERIODICALLY AS REQUIRED

Blow dirt out of the welder with low pressure air to
eliminate excessive dirt and dust buildup that could
cause welder to run hot.

Blow dirt out of: Rectifier & Fan Motor Assembly;
PC Board located on Case Side Assembly; and
Center Assembly components.

Vacuum accumulated dirt from gearbox and wire
feed section.

Inspect the incoming guide tube and clean inside
diameter if necessary. Replace when excessively
worn.

Replace Contact Tip

when hole is enlarged or

elongated (refer to

CHANGING THE CONTACT

TIP

, in this section).

Replace gas nozzle.

Replace Liner

when wire feeding problems occur

and other items have been checked (refer to

CHANGING LINER

procedure in this section).

Replace internal gun handle parts as necessary
(see Procedure at the end of this section).

WARNING