INSTALLATION
RED-D-ARC E300
A-3
STACKING
Installation of Field Installed Options
For installation of compatible field installed options,
see Field Installed Options section, and refer to the
instructions included with those options.
Output Cable Size and Connection
The output leads are connected to the output termi-
nals marked ‘+” and “-”. They are located at the lower
right and lower left corners of the front panel. The
E300 provides 1/2” studs for weld cable connections.
Minimum cable sizes recommended are listed in the
table below.
CABLE SIZES FOR COMBINED LENGTHS OF
COPPER ELECTRODE AND WORK CABLES
0-100 Ft.
100-150 Ft.
150-200 Ft.
200-250 Ft.
200 Amps
50% Duty Cycle
3 (30mm
2
)
2 (35mm
2
)
1 (45mm
2
)
1/0 (55mm
2
)
250 Amps
30% Duty Cycle
3 (30mm
2
)
2 (35mm
2
)
1 (45mm
2
)
1/0 (55mm
2
)
FALLING EQUIPMENT
can cause
injury.
• Do not lift this machine using lift bale if
it is equipped with a heavy accessory
such as undercarriage or gas cylinder.
• Lift only with equipment of adequate lifting capacity.
• Be sure machine is stable when lifting.
• Do not stack.
• Do not stack on top of any other type machine.
---------------------------------------------------------------------
WARNING
ELECTRIC SHOCK can kill.
• Turn the power switch of the
welding power source “OFF”
before connecting or disconnect-
ing output cables.
------------------------------------------------------------
WARNING