beautypg.com

Operation – Lincoln Electric IM606 RANGER 275 User Manual

Page 25

background image

B-9

OPERATION

B-9

RANGER 275

TABLE B.3

SUMMARY OF WELDING PROCESSES AND MACHINE SETTINGS

CONTROL

CABLE

USED

MODE

SWITCH

IDLER

SWITCH

OUTPUT

CONTROL

SWITCH

CONTACTOR

SWITCH

ELECTRODE

WHEN NOT

WELDING

TO START WELDING

PROCESS

STICK - CC

TIG - CC
K930-1 TIG MODULE /
K936-1 CONTROL CABLE
(With Amptrol)

WIRE FEED - CV,
LN-25 WITH 42V
REMOTE CON-
TROL KIT

WIRE FEED - CV,
LN-25 WITH
INTERNAL
CONTACTOR

WIRE FEED - CV,
LN-742

WIRE FEED - CV,
LN-7

Touch electrode to work.
Welding starts immediately
and engine goes to high idle.

Press Amptrol. Ranger 275
contactor closes. Welding
starts immediately and engine
goes to high idle.

Press gun trigger, Ranger
275 contactor closes.
Welding starts immediately
and engine goes to high idle.

Press gun trigger, LN-25
contactor closes. Welding
starts immediately and engine
goes to high idle.

Press gun trigger, Ranger
275 contactor closes.
Welding starts immediately
and engine goes to high idle.

Press gun trigger, Ranger
275 contactor closes.
Welding starts immediately.

NO

YES

YES

NO

YES

YES

AUTO

AUTO

AUTO

AUTO

AUTO

HIGH

STICK/TIG

or PIPE

STICK/TIG

WIRE FEED

WIRE FEED

WIRE FEED

WIRE FEED

LOCAL

REMOTE

REMOTE

LOCAL

REMOTE

REMOTE

WELDING

ON

CONTACTOR

CONTROLLED

CONTACTOR

CONTROLLED

WELDING

ON

CONTACTOR

CONTROLLED

CONTACTOR

CONTROLLED

HOT

COLD

COLD

COLD

COLD

COLD