beautypg.com

Troubleshooting, Caution – Lincoln Electric IM648 RED-D-ARC PYTHON User Manual

Page 27

background image

E-4

TROUBLESHOOTING

E-4

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your

Local Lincoln Authorized Field Service Facility

for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENTS(S)

RECOMMENDED

COURSE OF ACTION

When the trigger is pulled air begins
to flow, but there is no pilot arc after
at least 3 seconds.

The air begins to flow and there is a
very brief arc that snaps out consis-
tently with repeated trigger pulls.

The arc starts but sputters badly.

1. Check the torch consumables to be

sure they are not dirty or greasy,
and are in good shape. Replace
the consumables if necessary.

2. Make sure the air pressure is set

at 70 psi (75 psi for a 50 ft. torch).

3. Make sure there are no kinks or

restrictions for air flow in the torch
cable. Replace cable as needed.

4. If a slight thump cannot be felt in

the torch when the trigger is
pulled, check for loose connection
in the torch head and solenoid
assembly.

5. With machine turned off - input

power removed, and torch and
consumables connected - mea-
sure resistance on Output Power
board between B1 and B21. If
>10

Ω, possible fault in torch and

cable assembly.

6. Possible fault in Output board.

1. Check the torch consumables to

be sure they are in tight, not dirty
or greasy and in good shape.
Replace if necessary.

2. Make sure the air pressure is set

at 70 psi.

3. Possible fault in Output Power board.

1. Check the torch consumables to

be sure they are in tight, not dirty
or greasy and in good shape.
Replace if necessary.

2. Check air supply for oil or a great

deal of water. If there is oil or a
great deal of water, the air must
be filtered or the machine
switched to nitrogen or bottled air.

3. Make sure the air pressure is set at 70 psi.

If all recommended possible areas of
misadjustment have been checked
and the problem persists,

Contact

your local Lincoln Authorized
Field Service Facility.

PYTHON