beautypg.com

Lincoln Electric IM422 PRO-CUT 40 User Manual

Page 22

background image

– 22 –

Step

5 (con’t)

Test

Check *

12 (neg) to T3
(pos)
(3 phase only)

13 (neg) to T1
(pos)

13 (neg) to T2
(pos)

13 (neg) to T3
(pos)
(3 phase only)

12 (pos) to T1
(neg)

12 (pos) to T2
(neg)

12 (pos) to T3
(neg)
(3 phase only)

Test Result

>1K ohms

<100 ohms

<100 ohms

>1K ohms

<100 ohms

>1K ohms

<100 ohms

>1 K ohms

<100 ohms

>1K ohms

<100 ohms

>1K ohms

<100 ohms

>1K ohms

Conclusion

OK

Shorted

OK

Open

OK

Open

OK

Open

OK

Open

OK

Open

OK

Open

Next
Test
Step

1-2

1-2

1-2

1-2

1-2

1-2

1-2

Repair Action

Replace D9
Inspect S1
Test C1 and
C2

Replace D9
Inspect S1
Test C1 and
C2

Replace D9
Inspect S1
Test C1 and
C2

Replace D9
Inspect S1
Test C1 and
C2

Replace D9
Inspect S1
Test C1 and
C2

Replace D9
Inspect S1
Test C1 and
C2

Replace D9
Inspect S1
Test C1 and
C2