E-2

TROUBLESHOOTING

E-2

MULTI-WELD 350

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

Machine completely dead:
Input contactor does not pull in,

meters are off.

Meter turns on but input contator
does not pull in.

Thermal light comes on.

1. Check Input cable connections for

loose or faulty connection.

2. Input voltage may be too low.

3. The power switch may be faulty.

4. The DC Buss Power Supply PCB

or its connections may be faulty.

5. The Analog Control Power Supply

PCB may be faulty.

6. The Weld Control PCB may be

faulty.

1. Input to high

2. Remote receptacle output switch-

ing enabled.

3. The contactor or supply voltage to

contactor coil may be faulty.

4. The connections at PCB connec-

tors inside the control box may be
faulty.

5. The Peripheral PCB may be

faulty.

6. The Weld Control PCB may be

faulty.

1. Over- Temperature shut down.

2. The thermostat or imbalance pro-

tector or Peak Input Voltage
Protection (if present) or their con-
nections may be faulty.

3. Bad analog control Supply PCB.

4. Bad weld control PCB.

If all recommended possible areas of
misadjustment have been checked
and the problem persists, Contact
your local Lincoln Authorized
Field Service Facility.