beautypg.com

Maintenance – Lincoln Electric IM990 MAGNUM PRO 350 and 550 FUME GUNS User Manual

Page 21

background image

D-4

MAINTENANCE

D-4

6. Remove the two trigger terminals from the modular

trigger terminal housing.

7. Remove the incoming connector assembly (see

Item 8 Figure A.4, Installation Section) from the gun
cable.

8. Remove the damaged gun cable by sliding it rear-

ward from the vacuum hose.

9. Install the new gun cable by sliding it forward

through the vacuum hose.

10. Reassemble gun by reversing steps 1 through 7,

noting the following:

• Route trigger leads per this section Trigger

and Accessory Switch Lead Routings
(see figure D.1)

.

• Installation torques for both the incoming

connector and gun tube assemblies: 10 to 12
ft.-lbs..

• The order of connection of the trigger termi-

nals (red and white leads) to the trigger
assembly or in the Y connector is unimpor-
tant (non-polarized connections).

• Reassemble the Y connector by reversing

steps shown in 5.

• Install a new liner if it does not meet the cut

dimensional range given per this section
Liner Assembly Cleaning or Replacement

.

MAGNUM™ PRO 350 and 550 FUME GUNS