beautypg.com

Installation, Connect the gun to the wire feeder, Connect the gun to the fume collection system – Lincoln Electric IM990 MAGNUM PRO 350 and 550 FUME GUNS User Manual

Page 13

background image

A-6

INSTALLATION

MAGNUM™ PRO 350 and 550 FUME GUNS

A-6

5. REMOVING THE FUME TUBE ASSEMBLY

(See figure A.7)

Figure A.7

• Loosen locking collar (counter clockwise, right-hand

threads) on fume tube. Gas diffuser may remain in
place.

• Slide the fume tube out of the gun handle.

• Slide the fume tube off of the gun tube.

• Fume tube removed.

CONNECT THE GUN TO THE WIRE
FEEDER

1. Make sure that the gun locking knob is loosened.

Insert the gun into the gun conductor block and
tighten the gun locking knob.

2. Make the gas connection from the feeder to the gun

(if required).

3. Plug the trigger harness into the gunʼs Y-connector.

Plug the trigger harnessʼ connector into the recep-
tacle on the front of the feeder.

CONNECT THE GUN TO THE FUME
COLLECTION SYSTEM

1. Speed setting for Lincoln Miniflex system: “High” is

preferred for maximum fume collection.

2. Automatic / Manual setting (where available): Set to

“Manual” mode so that fume collection system will
continue running after welding. This ensures maxi-
mum cooling of the gun. Fume collection system or
gate valve to the gun may be shut off or closed after
the gun has cooled for 10 minutes since the last

weld.

CONSUMABLE PARTS

Contact tips

See Table A.3

Gas diffuser assembly

KP2747-1

Gas nozzle assembly, 5/8 inch opening

KP2743-2-62R

Fume collection nozzles See Figure A.6