beautypg.com

Installation, Caution – Lincoln Electric IM922 LN-23P User Manual

Page 10

background image

A-3

INSTALLATION

LN™-23P

A-3

DC-600: Attach the triangular mounting plate to the
shock mounted plate of the Adapter with three of
the #10 self-tapping screws provided. Attach the
triangular plate to the side of the DC-600 adjacent
to the control terminal strips using two roof screws
and one front panel screw. Connect the Adapter
control cable to the DC-600 terminal strips power
the proper connection diagram.

Other Power Sources: Mount the Adapter Kit to the
side of the power source or some convenient loca-
tion so its control cable can be connected to the
power source 14 pin connector. Use the shock
mounted mounting plate as a template to locate the
four 5/32" diameter holes that must be drilled in the
case side. (Use caution not to drill into or get chips
into any internal components.) Mount the Adapter
Kit with four of the #10 self-tapping screws provid-
ed. Connect the Adapter control cable to power
source terminal strips per the proper connection
diagram.

K-276 ENCLOSED 50lb. WIRE REEL SUPPORT
Installation and loading instructions (M-13153) are
supplied with the kit.

------------------------------------------------------------------------

WIRE DRIVE ROLLS AND GUIDE TUBES

The LN™-23P is shipped with the proper drive rolls
and guide tubes factory installed. Do not adjust the
idle roll tension adjusting screw. If the idle roll tension
must be relieved temporarily, see “A” and “B” of
Maintenance Section.

OPTIONAL FEATURES INSTALLATION

INNERSHIELD GUN AND CABLE

Unclip the rubber retaining strap that holds the wire
enclosure cover in place and remove the cover.

Push the wire drive section door latch towards the
rear of LN™-23P and open door.

Loosen the gun locking set screw in the conductor
block on the front of the gear box with a 3/16 hex
Allen wrench.

Lay the cable out straight. Insert the connector on
the conductor cable thru the large grommet in the
front of the wire drive section and into the brass
block on the front of the gear box. Make sure it is
all the way in and tighten the locking set screw with
a 3/16 hex Allen wrench. Keep this connection
clean and bright.

Connect the 3 pin gun trigger connector to the
lower receptacle.

If the gun cable being used has a reduced speed
switch, connect the 4 pin reduced speed switch
connector to the upper receptacle. If the reduced
speed switch is not used, install the protective cap
on the upper receptacle.

K-350 ADAPTER KIT– Turn off power source and all
power to power source.

SAM-400 Engine Welders: Attach the shock
mounted mounting plate to the front of the SAM
electrical component panel to left of the relay case
with 4 of the #10 self-tapping screws provided.
Older models require the drilling of 4 5/32 dia.
holes into the panel. Connect the adapter control
cable to the SAM terminal strips per the proper
connection diagram.

CAUTION