A-4

INSTALLATION

LF-72

A-4

SAFETY PRECAUTION

ELECTRIC SHOCK can
kill.

• Only qualified personnel should

perform this installation.

• Turn off the input power to the power source at

the disconnect switch or fuse box before work-
ing on this equipment. Turn off the input power
to any other equipment connected to the weld-
ing system at the disconnect switch or fuse
box before working on this equipment.

• Do not touch electrically hot parts.

----------------------------------------------------------------------

** Tabled values are for operation at ambient temperatures of 40°C and below. Applications above 40°C

may require cables larger than recommended, or cables rated higher than 75°C.

Amperes

200
200
225
225
250

250
250
250
300

325
350
400
400
500

Percent

Duty

Cycle

60

100

20

40 & 30

30

40
60

100

60

100

60
60

100

60

200 to 250 Ft.

61 to 76 m

1/0
1/0
1/0
1/0
1/0

1/0
1/0
1/0
2/0

3/0
3/0
4/0
4/0
4/0

150 to 200 Ft.

48 to 61 m

1
1
1
1
1

1
1
1

1/0

2/0
2/0
3/0
3/0
3/0

100 to 150 Ft.

31 to 48 m

2
2
2
2
2

1
1
1
1

2/0
2/0
2/0
3/0
3/0

50 to 100Ft.

15 to 31 m

2
2
3
3
3

2
1
1
1

2/0
1/0
2/0
3/0
2/0

0 to 50 Ft.

0 to 15 m

2
2

4 or 5

3
3

2
1
1
1

2/0
1/0
2/0
3/0
2/0

RECOMMENDED CABLE SIZES (RUBBER COVERED COPPER - RATED 75°C)**

CABLE SIZES FOR COMBINED LENGTHS OF ELECTRODE AND WORK CABLES

WELD CABLE SIZES

Table A.1 has the copper cable sizes recommended
for different currents and duty cycles. Lengths stipu-
lated are the distance from the welder to work and
back to the welder again. Cable sizes are increased
for greater lengths primarily for the purpose of mini-
mizing voltage in the welding circuit.

TABLE A.1