beautypg.com

Troubleshooting, Caution – Lincoln Electric IM592 INVERTEC V200-T User Manual

Page 22

background image

E-2

TROUBLESHOOTING

E-2

INVERTEC V200-T

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENTS(S)

RECOMMENDED

COURSE OF ACTION

The machine is dead - no output -
no fan.

No output but the fan operates nor-
mally.

Output turns on momentarily, then
switches off.

No output - Main input fuses open,
indicating excessive current draw.

1. The input power switch must be

in the ON position.

2. Make sure the input voltage is

correct for the machine.

3. Check continuity of the 0.5-amp

slow blow fuse located on the
P.C. Board.

1. The machine may be overheated.

Check the thermal indicator light.
Wait for the machine to cool and
the thermostats to reset.

1. Check the input voltage. Make

sure the input voltage is correct
for the machine.

1. Inspect input leads for possible

shorts or grounds or mis-connec-
tions.

2. Install new fuses and reapply

power. If fuses open again, con-
sult a Lincoln Authorized Field
Service Facility.

If all recommended possible areas of
misadjustment have been checked
and the problem persists, Contact
your local Lincoln Authorized Field
Service Facility.