beautypg.com

Installation – Lincoln Electric IM904 INVERTEC STT II User Manual

Page 8

background image

INVERTEC STT II (CE)

A-1

INSTALLATION

A-1

STANDARD VOLTAGE

INPUT CURRENT AT RATED OUTPUT

200/220/380/415/440/3/50/60 HZ

33/30/18/17/16

TECHNICAL SPECIFICATIONS –INVERTEC STT II (CE) (For Code 11366)

INPUT- THREE PHASE ONLY

RATED OUTPUT

RECOMMENDED INPUT WIRE AND FUSE SIZES

I

NPUT VOLTAGE

FUSE(SUPER LAG)

INPUT AMPERE

TYPE 75°C

TYPE 75°C

AND FREQUENCY

OR BREAKER

RATING ON

COPPER

COPPER

SIZE

NAMEPLATE

SUPPLY WIRE

GROUND WIRE

IN CONDUIT

IN CONDUIT

AWG (IEC) SIZES

AWG (IEC) SIZES

200/50/60

40

33

220/50/60

40

30

10 (6 mm2)

10 (6 mm2)

380/50/60

30

18

415/50/60

30

17

440/50/60

30

16

HEIGHT

WIDTH

DEPTH

WEIGHT

23.2 in

13.2 in.

24.4 in.

100 lbs.

589 mm

336 mm

620 mm

46 kg

OUTPUT

DUTY CYCLE

AMPS

VOLTS AT RATED AMPS

60% Duty Cycle

225

29

100% Duty Cycle

200

28

CURRENT RANGE

OPEN CIRCUIT VOLTAGE

AUXILIARY POWER

Peak Current

1

0 - 450 Amps

85 VDC Maximum

115

2

VAC @ 4 Amps

Background 0 - 125 Amps

42 VAC @ 4 Amps

1

At low input voltages (below 208 VAC) and input voltages of 380 VAC through 415 VAC there may be a 15% reduction in Peak Current.

2

115 VAC not present on European Models.

PHYSICAL DIMENSIONS