A-5

INSTALLATION

A-5

INVERTEC STT II (CE)

FIGURE A.2 RECONNECT PANEL

INPUT VOLTAGE RECONNECT
PROCEDURE

As shipped from the factory, multiple voltage
machines are internally configured for the highest
input voltage (440-460 VAC), for Code 11366 and
(380-415 VAC), for Code 11367.

1. For Connections to 440 or 460 VAC

verify

the

internal configurations to the procedures shown
below and refer to Figure A.2.

2. For Connections to 200,208,220,230,380,400 or

415 VAC follow the procedure shown below and
refer to figure A.2.

NOTE: Turn main power to the machine OFF
before performing the reconnect procedure.
Failure to do so will result in damage to the
machine. DO NOT switch the reconnect bar with
machine power ON.
------------------------------------------------------------------------

To Operate at

Procedure

460 or 440 VAC

1. Open reconnect panel

(Code 11366)

access door on wraparound.

2. Move input voltage switch

to Voltage = 380-460V pos-
ition.

3. Move lead

A

to 440-460

Terminal.

380 or 415 VAC

1. Open reconnect panel

(Codes 11366)

access door on wraparound.

2. Move input voltage switch

to Voltage = 380-460V
position.

3. Move lead

A

to 380-415

Terminal.

380,400 or 415 VAC

1. Open reconnect panel

(Codes 11367)

access door on wraparound.

2. Move input voltage switch

to Voltage = 380-415V
position.

3. Move lead

A

to 380-415

Terminal.

220 or 230 VAC

1. Open reconnect panel

(Codes 11366)

access door on wraparound.

2. Move input voltage switch

to Voltage = 200 -230V
position.

3. Move lead

A

to 220-230

Terminal.

200 or 208 VAC

1. Open reconnect panel

(Codes 11366)

access door on wraparound.

2. Move input voltage switch

to Voltage = 200 -230V
position.

3. Move lead

A

to 200-208

Terminal.

200 or 208 VAC

1. Open reconnect panel

(Codes 11367)

access door on wraparound.

2. Move input voltage switch

to Voltage = 200 -230V
position.

3. Move lead

A

to 200-208

Terminal.

OUTPUT CONNECTIONS

WIRE FEEDER OUTPUT CONNECTIONS

Refer to the Accessories section of this manual for instructions
on connecting a wire feeder to the INVERTEC STT II (CE).