beautypg.com

Troubleshooting, Caution pc board troubleshooting guide – Lincoln Electric IM602 IDEALARC DC-655 User Manual

Page 36

background image

E-10

TROUBLESHOOTING

E-10

DC-655

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

PC BOARD TROUBLESHOOTING GUIDE -

THERMAL FAN/ SNUBBER P.C.

BOARD

NOTE:

Fan will run for minimum of 5 minutes once fan turns on.

1. LED1 when ON indicates fan should be running. If ON and machine is cold, replace PCB.
2. LED2 when ON indicates welding current greater than 50 amps. If ON and not drawing more than 40 amps,

replace PCB.

3. LED3 when ON indicates Main SCRʼS need cooling and turns fan ON. If ON and machine is cold, replace

PCB.

4. LED4 when ON indicates an open Thermal Fan Thermistor, or open connection to PCB. Fan will run constant-

ly. Check Thermal Fan Thermistor for an open. If open replace. If not open Replace PCB.

5. LED5 when ON indicates an open thermostat. Thermal Protection light should also be ON. If Thermal

Protection light is not ON, and LED5 is ON, replace PCB.

6. LED6 when ON indicates fan should be running. LED6 will be ON whenever LEDʼs 2, 3 4 or 5 is ON. If LEDʼs

2, 3, 4, or 5 are not ON when LED6 is ON, replace PCB.