E-6

P.C. BOARD TROUBLESHOOTING GUIDE

E-6

IDEALARC

®

DC-1500

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

OUTLINE FOR DC-1500 TROUBLESHOOTING GUIDE

NO WELDER OUTPUT

MACHINE HAS OUTPUT BUT

ERRATIC WELDING

(INPUT CONTACTOR “ON” TERMINALS 2 AND 4 CLOSED)

TRIPS OFF IMMEDIATELY

CHECK PROCEDURE

CHECK CONTROL BOARD

CHECK FOR SHORT

LED L5

BETWEEN ELECTRODE AND

CHECK MODE SWITCH FOR

WORK LEADS, REMOVE

PROPER POSITION FOR

EXTERNAL LEADS FROM

PROCESS BEING USED

IF OFF

IF ON

THE OUTPUT TERMINALS

CHECK LED’S

CHECK LED L1

CHECK “FIRING” BOARD

IF TROUBLE STILL

L4, L5, L6

LED’S

PERSISTS,

FOR EQUAL

IF OFF

IF ON

CHECK LED L3 ON

BRILLIANCY

ALL

“CONTROL/FAULT

CHECK AC

REPLACE

NINE LIGHTS

PROTECTION” BOARD

IF LIGHTS ARE NOT ALL

INPUT TO

“CONTROL/

SHOULD

APPROXIMATELY EQUAL

“CONTROL/

FAULT

BE ON

IF LIGHT GOES ON,THEN

BRIGHT, REPLACE

FAULT

PROTECTION”

QUICKLY OUT WHEN START

FIRING P.C. BOARD

PROTECTION”

BOARD

IF YES

BUTTON IS PRESSED,

BOARD

IF NO

“CONTROL/FAULT

POSSIBLE

CHECK GATE

PROTECTION” BOARD IS

DEFECTIVE T7

LEAD

CHECK

DEFECTIVE AND SHOULD

TRANSFORMER

CONNECTIONS

LED’S

BE REPLACED

TO SCR’S

L7, L8, L9

IF ONE

IF ON AND

OR MORE

OTHER LIGHTS

ARE OUT

ARE OUT

CHECK AC

REPLACE

INPUT TO

FIRING

BOARD,

BOARD

203-204, 205-206

207-208

POSSIBLE

DEFECTIVE

TRANSFORMERS
T2, T3, OR T4

Have an electrician install and
service this equipment.

Turn the input power off at the
fuse box before working on
equipment.

Do not touch electrically hot parts.

ELECTRIC SHOCK

can kill.

WARNING

TABLE E.1