E-6
P.C. BOARD TROUBLESHOOTING GUIDE
E-6
IDEALARC
®
DC-1500
Observe all Safety Guidelines detailed throughout this manual
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
CAUTION
OUTLINE FOR DC-1500 TROUBLESHOOTING GUIDE
NO WELDER OUTPUT
MACHINE HAS OUTPUT BUT
ERRATIC WELDING
(INPUT CONTACTOR “ON” TERMINALS 2 AND 4 CLOSED)
TRIPS OFF IMMEDIATELY
CHECK PROCEDURE
CHECK CONTROL BOARD
CHECK FOR SHORT
LED L5
BETWEEN ELECTRODE AND
CHECK MODE SWITCH FOR
WORK LEADS, REMOVE
PROPER POSITION FOR
EXTERNAL LEADS FROM
PROCESS BEING USED
IF OFF
IF ON
THE OUTPUT TERMINALS
CHECK LED’S
CHECK LED L1
CHECK “FIRING” BOARD
IF TROUBLE STILL
L4, L5, L6
LED’S
PERSISTS,
FOR EQUAL
IF OFF
IF ON
CHECK LED L3 ON
BRILLIANCY
ALL
“CONTROL/FAULT
CHECK AC
REPLACE
NINE LIGHTS
PROTECTION” BOARD
IF LIGHTS ARE NOT ALL
INPUT TO
“CONTROL/
SHOULD
APPROXIMATELY EQUAL
“CONTROL/
FAULT
BE ON
IF LIGHT GOES ON,THEN
BRIGHT, REPLACE
FAULT
PROTECTION”
QUICKLY OUT WHEN START
FIRING P.C. BOARD
PROTECTION”
BOARD
IF YES
BUTTON IS PRESSED,
BOARD
IF NO
“CONTROL/FAULT
POSSIBLE
CHECK GATE
PROTECTION” BOARD IS
DEFECTIVE T7
LEAD
CHECK
DEFECTIVE AND SHOULD
TRANSFORMER
CONNECTIONS
LED’S
BE REPLACED
TO SCR’S
L7, L8, L9
IF ONE
IF ON AND
OR MORE
OTHER LIGHTS
ARE OUT
ARE OUT
CHECK AC
REPLACE
INPUT TO
FIRING
BOARD,
BOARD
203-204, 205-206
207-208
POSSIBLE
DEFECTIVE
TRANSFORMERS
T2, T3, OR T4
•
Have an electrician install and
service this equipment.
•
Turn the input power off at the
fuse box before working on
equipment.
•
Do not touch electrically hot parts.
ELECTRIC SHOCK
can kill.
WARNING
TABLE E.1