Installation, Technical specifications – Lincoln Electric IM841 INVERTEC V450-PRO User Manual
Page 8
INVERTEC® V450-PRO
A-1
INSTALLATION
A-1
TECHNICAL SPECIFICATIONS -
INVERTEC® V450-PRO
OUTPUT
RECOMMENDED INPUT WIRE AND FUSE SIZES FOR MAXIMUM RATED OUTPUT
PHYSICAL DIMENSIONS
TEMPERATURE RANGES
INPUT AT RATED OUTPUT - THREE PHASE ONLY
INPUT VOLTS-
FREQUENCY
208/230/460/575V - 60HZ.
200/220/440/575V - 50HZ.
INPUT
VOLTAGE /
FREQUENCY
208/50/60HZ
230/50/60HZ
460/50/60HZ
575/50/60HZ
HEIGHT
26.10 in
663 mm
WIDTH
19.86 in
505 mm
DEPTH
32.88 in
835 mm
WEIGHT
293 lbs.
133 kg.
TYPE 75°C
(SUPER LAG)
OR BREAKER
SIZE (AMPS)
100
100
50
40
TYPE 75°C
GROUND WIRE IN CON-
DUIT AWG(MM
2
)
SIZES
8(10)
8(10)
10(6)
10(6)
TYPE 75°C
COPPER WIRE IN
CONDUIT AWG(MM
2
)
SIZES
4(25)
4(25)
8(10)
10(6)
MIG/MAG
FCAW
SMAW
GTAW
Pulse
50-570 Average Amps
40-570 Average Amps
55-570 Average Amps
5-570 Average Amps
5-750 Peak Amps
30-76
76
76
18-76
76
PULSE
VOLTAGE
RANGE
5 - 55 VDC
AUXILIARY POWER
(CIRCUIT BREAKER PROTECTED)
24VAC
42VAC AT
10 AMPS
115VAC AT
15* AMPS
PULSE AND
BACKGROUND
TIME RANGE
100 MICRO SEC. -3.3
SEC.
PULSE
FREQUENCY
0.15 - 1000 Hz
INPUT
CURRENT
AMPS
58/53/25/22
82/78/37/31
49/45/23/18
67/61/31/25
IDLE
POWER
400 Watts
Max.
POWER FACTOR
@ RATED OUTPUT
.95 MIN.
EFFICIENCY
@ RATED
OUTPUT
88%
OUTPUT
CONDITIONS
AMPS / VOLTS / DUTY CYCLE
570A@43V. 60%
500A@40V. 60%
OPERATING TEMPERATURE RANGE
-20°C to +40°C
STORAGE TEMPERATURE RANGE
-40°C to +40°C
OPEN CIRCUIT VOLTAGE PROCESS CURRENT RANGE (DC) CURRENT
* Earlier models used 10 amps circuit breaker.