CONNECTIONS OF WIRE FEEDERS TO V450-PRO

LF-72, 74 Connection Instructions
• Turn the Invertec power switch "off".
• Connect the K1797-[ ] control cable from the LF-72, 74

to the 14-pin MS-style connector.

• Connect the electrode cable to the output terminal of

the polarity required by electrode. Connect the work
lead to the other terminal.

If a remote control such as K857 is to be used with the

LF-72, 74 the remote can be connected directly to the
6-pin MS-style connector on the front of the Invertec or
use a K864 adapter to connect the LF-72, 74 and the
remote to the 14-pin MS-style connector.

LN-10, DH-10 Connection Instructions

• Turn the Invertec power switch "off"
• Connect the K1505 control cable from the LN-10 to the

14-pin MS-style connector.

• Connect the electrode cable to the output terminal of

polarity required by the electrode. Connect the work
lead to the other terminal.

• Set the meter polarity switch on the front of the Invertec

to coincide with wire feeder polarity used.

• See the LN-10 manual for details on accessing Control

DIP Switch. Dip Switches for the V350 and the same
settings may be used for the V450.

LN-15 Connection Instructions
(See Figure A.4)
• Turn the Invertec power switch "off".
• Connect the electrode cable to the output terminal of

polarity required by electrode. (See Figures below)

• Set the meter polarity switch on the front of the Invertec to

coincide with wire feeder polarity used.

LN-25 Connection Instructions
• Turn the Invertec power switch "off".
• Connect the electrode cable to the output terminal of

polarity required by electrode. Connect the work lead to
the other terminal.

• LN-25 with Remote Control 6-Pin (K444-1) and 14-pin

(K444-2) remotes can be connected directly to the 6-pin &
14-pin MS-style connectors. The 42 Volt Remote Voltage
and Output Control (K624-1) Kit can be connected to the
V450’s 14-pin MS-style connector using Remote Control
Cable assembly K627- [ ]. LN-25s with a K431-1 remote
kit can be connected to the V450’s 14-pin MS-style con-
nector using a K432 cable and K876 adapter. (See con-
nection diagram S19899). Or the K432 cable could be
modified with a K867 Universal Adapter Plug (See con-
nection diagram S19405) to connect it to the V450’s 14-
pin MS-style connector.

14-PIN

STUD

WORK CLAMP

ELECTRODE CABLE

V450-PRO

ACROSS THE ARC MODEL

CONROL CABLE MODEL

OUTPUT TERMINALS
ALWAYS HOT.

POWER SOURCE CONTACTOR
SWITCH MUST BE IN THE
“ON” POSITION OR USE A
K848 JUMPER PLUG KIT.

MAGNUM GUN
AND CABLE
ASSEMBLY

LN-15
SEMIAUTOMATIC
WIRE FEEDER
K1870-1

14-PIN

STUD

ELECTRODE CABLE

V450-PRO

K1819-10
CONTROL CABLE

MAGNUM GUN
AND CABLE
ASSEMBLY

LN-15
SEMIAUTOMATIC
WIRE FEEDER
K1871-1 MODEL

FIGURE A.4