INVERTEC V350-PIPE
INPUT AC VOLTAGE & DC OUTPUT
Ordering
Input AC
Rated DC Output Output
Information Voltage
Amps/Volts/Duty Cycle
Range
(continuous)
200
208-230/
K1728-10
380-400/
350A / 34V / 60%
415-460/
AMPS
575
300A / 32V /100%
5-425
1& 3 Phase
60/50 Hz
* Overall Length Including Handle, 27.8” (706mm)
Voltage
200
208
230
380
400
415
460
575
200
208
230
380
400
415
460
575
Phases
1
1
1
1
1
1
1
1
3
3
3
3
3
3
3
3
300Amps @
32Volts(100%)
Not
Recommended
76
69
Not
Recommended
Not
Recommended
41
36
31
41
39
36
23
22
22
19
16
350Amps @
34Volts(60%)
Not
Recommended
94
85
Not
Recommended
Not
Recommended
64
42
37
50
50
42
28
27
26
23
18
Line Cord
AWG
2
4
---
6
8
8
8
6
8
8
8
8
8
8
Fuse size
---
125A
125A
---
---
80A
70A
50A
80A
80A
70A
50A
50A
50A
50A
35A
V350-PIPE INPUT CURRENT
OUTPUT CABLES, CONNECTIONS AND LIMITATIONS
Recommended Fuse Sizes Base On The U.S. National Electrical Code And Maximum Machine Outputs
Input 50/60 Hz
Output
Recommended
Note 1. Not rated is indicated by 4-x’s in the box on the rating plate.
Note 2. When operating on these inputs, the line cord should be changed to an input conductor of 6 AWG or larger.
Select The output cable size based upon the following chart.
Cable sizes for Combined Length of Electrode and Work Cable (Copper) 75C rated:
DUTY CYCLE
100%
60%
CURRENT
300
350
LENGTH UP TO 200FT.(61m)
1/0
1/0
200-250 FT. (61-76m)
1/0
2/0
Notes
Note 1
Note 2
Note 2
Note 1
Note 1
Note 2
Note 2
Note 2
PHYSICAL DIMENSIONS
HEIGHT
14.8 in(373 mm)
WIDTH
13.3 in(338 mm)
DEPTH*
27.8 in(706 mm)
WEIGHT
81.5 lbs.(37.0 kg.)
TEMPERATURE RANGES
STORAGE TEMPERATURE RANGE
-40°F to 104°F(-40°C to 40°C)
OPERATING TEMPERATURE RANGE
-4°F to 104°F(-20°C to 40°C)
Product
Name
Invertec
V350-
PIPE
6
60
0//5
50
0 H
Hzz
Open
Circuit
Voltage
80VDC