Operation, Warning general description – Lincoln Electric IM743 INVERTEC V350-PIPE User Manual
Page 12

B-1
OPERATION
V350-PIPE
B-1
SAFETY PRECAUTIONS
ELECTRIC SHOCK can kill.
•
Do not touch electrically live parts or
electrode with skin or wet clothing.
•
Insulate yourself from work and
ground.
•
Always wear dry insulating gloves.
------------------------------------------------------------------------
FUMES AND GASES can be danger-
ous.
•
Keep your head out of fumes.
•
Use ventilation or exhaust to remove
fumes from breathing zone.
------------------------------------------------------------------------
WELDING SPARKS can cause fire or
explosion.
•
Keep flammable material away.
•
Do not weld on closed containers.
------------------------------------------------------------------------
ARC RAYS can burn eyes and skin.
•
Wear eye, ear and body
protection.
------------------------------------------------------------
See additional warning information at
front of this operator
’
s manual.
-----------------------------------------------------------
WARNING
GENERAL DESCRIPTION
The Invertec V350-PIPE offers DC Stick and CV-
Innershield welding.
DUTY CYCLE
The V350-PIPE is rated at 350 amps, 60% duty cycle
(based on a 10 minute cycle). It is also rated at 275
amps, 100% duty cycle.
OPERATIONAL FEATURES and CONTROLS:
UPPER CONTROL PANEL
1. AMPS Meter
•
Prior to STICK operation (current flow), the meter
displays preset current value (either 2 amps or +/-
3% (e.g. 3 amps on 100), whichever is greater).
•
Prior to CV operation, the meter displays four dash-
es indicating non-presettable AMPS.
•
During welding, this meter displays actual average
amps.
•
After welding, the meter holds the actual current
value for 5 seconds. Output adjustment while in the
"hold" period results in the "prior to operation" char-
acteristics stated above. The displays blink indicat-
ing that the machine is in the "Hold" period.
2. VOLT METER
•
Prior to CV operation (current flow), the meter dis-
plays desired preset voltage value (+/- .5V).
•
Prior to STICK operation, the meter displays the
Open Circuit Voltage of the Power Source or four
dashes if the output has not been turned on.
•
During welding, this meter displays actual average
volts.
•
After welding, the meter holds the actual voltage
value for 5 seconds. The displays blink indicating
that the machine is in the "Hold" period.
•
Output adjustment while in the "hold" period results
in the "prior to operation" characteristics stated
above.
3. OUTPUT CONTROL
•
Output control is conducted via a single turn poten-
tiometer.
•
Adjustment is indicated by the meters as stated
above.
4. WELD TERMINALS-REMOTE / ON
•
Two status lights indicate the location of trigger con-
trol as determined by the "WELD TERMINALS"
push button.
•
If trigger control is local "weld terminals on", the ON
display will be lit.
•
If trigger control is remote "weld terminals remotely
controlled", the REMOTE display will be lit.
•
The unit will power up in "pre-determined preferred"
trigger modes.
STICK = ON
CV = ON or REMOTE depending if remote output
controls are connected to the machine.
These trigger modes can be over-ridden (switched) with the
WELD TERMINALS push button. When changed, the unit
will power up in the configuration it was in when it was last
powered down.