Installation, Physical dimensions, Rated output & additional output capacity – Lincoln Electric IM609 SQUARE WAVE TIG 275 User Manual
Page 9

A-2
INSTALLATION
SQUARE WAVE TIG 275
A-2
TECHNICAL SPECIFICATIONS - Square Wave TIG 275 (K1618-1)
For AC/DC Stick, DC TIG and Balanced AC TIG
Welding at 275A 40% Duty Cycle
w/o Optional K1620-1 Power Factor Capacitors
Based on the 1996 U.S. National Electrical Code
For Unbalanced AC TIG Welding above 180A,
255A 40% Duty Cycle, Maximum Penetration
w/o Optional K1620-1 Power Factor Capacitors
Based on the 1996 U.S. National Electrical Code
INPUT - SINGLE PHASE ONLY
RECOMMENDED INPUT WIRE AND FUSE SIZES
Input
Voltage /
phase/
Frequency
220/1/50/60
380/1/50/60
415/1/50/60
Input
Amperes
106
60
55
Type 75°C
Copper Ground
Wire in
Conduit AWG
(IEC) Sizes
6 (13.3 mm2)
8 (8.4 mm2)
8 (8.4 mm2)
Fuse
(Super Lag)
or Breaker
Size
(1)
125
70
70
Type 75°C
Copper Wire in
Conduit AWG
(IEC) Sizes
40°C (104°F) Ambient
4 (21.2 mm2)
8 (8.4 mm2)
8 (8.4 mm2)
Type 75°C
Copper Ground
Wire in
Conduit AWG
(IEC) Sizes
6 (13.3 mm2)
8 (8.4 mm2)
8 (8.4 mm2)
Type 75°C
Copper Wire in
Conduit AWG
(IEC) Sizes
40°C (104°F) Ambient
3 (25.0 mm2)
6 (13.3 mm2)
6 (13.3 mm2)
Input
Amperes
139
79
72
Height
Width
Depth
Weight
Power
24.06 in.
19.15 in.
28.00 in.
Approx. 340 lbs.
Source
611 mm
486 mm
711 mm
154 kg.
Lift Hook add 3.57” (91 mm)
Power Source
33.40 in.
27.65 in.
40.65 in.
Approx. 385 lbs.
on
848 mm
702 mm
1033 mm
175 kg.
Undercarriage
PHYSICAL DIMENSIONS
Fuse
(Super Lag)
or Breaker
Size
(1)
175
90
90
(1)
Also called “inverse time” or “thermal/magnetic” circuit breakers; circuit breakers which have a delay in tripping action that decreases as the magnitude of cur-
rent increases.
Code
Number
10524
Input Current at
Input Current at
Input Current at Idle Current Idle Power
40% Duty Cycle
60% Duty Cycle
100% Duty Cycle
DC STICK,
DC STICK,
DC STICK,
DC TIG,
UNBALANCED AC TIG DC TIG,
UNBALANCED AC TIG DC TIG,
UNBALANCED AC TIG
BALANCED AC TIG
BALANCED AC TIG
BALANCED AC TIG
99/57/52
139/79/72
83/45/421 12/64/59
63/36/33
86/49/45
8/6/5
900 WMax.
Standard
Voltage
220/380/415/1/50/60
RATED OUTPUT & ADDITIONAL OUTPUT CAPACITY
Duty Cycle
Amps
Volts at Rated Amperes
Current Range
Auxiliary Power
40% Duty Cycle AC/DC Stick
275 A
31.0 V
5-315 Amps
220 Volts AC, 2 Amps
NEMA Class II (40) AC/DC TIG
255 A
20.2 V
Schuko Receptacle
and 2 Amp Circuit Breaker
60% Duty Cycle AC/DC Stick
225 A
29.0 V
MAX O.C.V.
AC/DC TIG
200 A
18.0 V
AC & DC 80V
100% Duty Cycle AC/DC Stick
175 A
27.0 V
Normal O.C.V.
AC/DC TIG
150 A
16.0 V
72 V (AC) 59 V (DC)