Logging off, Ogging – ADC ETU-751C User Manual

Page 55

background image

700-701-100-02

System

Configuration

UTU-701 and ETU-751 List 1

August 9, 2002

45

3

Do one of the following:

Type

to keep the current settings.

Type

to reset values to factory defaults. The system resets and both LTU and NTU units go through

their respective synchronization processes. If loops are down or are in update mode while Set to Factory
Dflts
is enabled, only the local unit will restart. If the loops are up, both the LTU and NTU will restart.

The factory default system settings are listed in

Table 22

.

L

OGGING

O

FF

If the maintenance terminal must be left unattended for any length of time, log off until work resumes. This
prevents unauthorized persons from inadvertently changing operating parameters.

Log off by choosing Quit from the menu bar or by disconnecting the cable connecting the maintenance terminal
to the line or desktop unit. Automatic log off occurs after 20 minutes of keyboard inactivity.

Table 22.

Factory Default System Settings

Operating Option

Default Setting

System Settings

Application Mode

SINGLE

HDSL Rate Mode

MANUAL

HDSL Payload Rate

256kbps/4

Remote Console Access

ALLOWED

Protect Switch Command

Not supported on these units.

Local Unit Role

NTU

LTU/NTU Interface

G,703 port

Interface Type

G.703

Data Rate/# of TSs

256 / 4

Beginning TS

0 (structured mode)
1 (unstructured mode)

Alarms LTU/NTU Interface

Loss of Clock (LOC)

MIN (Minor)

Alarms HDSL Spans

Margin (MAR)

MIN (Minor)

Margin Threshold

6

Errored Seconds (ES)

MIN (Minor)

24 Hour ES Threshold

70

Loss of Sync Word (LOSW)

MAJ (Major)

Power Feed Open (PFO)

Not supported on these units.

Power Feed Short (PFS)

Not supported on these units.

N

Y