3.3 Pump 1 (Two speed, no 24HR circulation pump fitted)
Pump 1 is controlled by just one touch pad button pushing the pump button 4 times cycles its
operation through 4 modes Automatic, Manual Low Speed, Manual High Speed and Standby. When
the spa is running in automatic mode, pressing the pump 1 button will deactivate auto mode and set
the pump running in Manual low speed. The auto LED is orange when auto mode is enabled and off
when in manual low speed or manual high speed. When the pump is in standby mode all indicator
LED’s are off.
Push 1 (Manual Low Speed)
Push 2 (Manual High Speed)
Push 3 (Standby Mode)
Push 4 (Auto Mode)
Notes:
1) If Pump 1 is left in ”Manual or “Standby” modes, it will automatically revert to “Auto” mode after 90
minutes.
2) There is no direct user control over the heater. The heater may come on automatically whenever
Pump 1 is on.
3) If the heater element is on, running the pump in high speed may cause the heater to load shed and
switch off.
3.4 Pump 1 (Two speed, 24HR circulation pump fitted)
Pushing the pump button three times cycles the pump through its two speeds then off. The pump LED
is green when the pump is running in low or high speed and off when pump is off.
Push 1 (Low Speed)
Push 2 (High Speed)
Push 3 (Pump off)
Notes:
1) If Pump 1 is left on, it will automatically switch off after 20 minutes.
2) There is no direct user control over the heater. The heater may come on automatically whenever
the 24hr circulation pump is on.
3) If the heater element is on, running the pump in high speed may cause the heater to load shed
and switch off. If this occurs the heater will come back on approximately 5 seconds after the pump
is deselected.
3 Pump Operation
There are four possible variations of pump 1 that may have been fitted to your spa, this user guide
covers all variations of pump 1 that could have been fitted. Please read sections 3.1 through to 3.4
then follow the section which matches your spa operation.
Note: Even if a 24hr circulation pump is fitted there is no button to control it. The 24hr circulation pump
operation is completely automatic, It only turns off in sleep mode (if optional time clock is fitted) or in
an error condition.
3.1 Pump 1 (Single speed pump, no 24hr circulation pump fitted)
Pump 1 is controlled by just one touch pad button pushing the pump button three times cycles its
operation through three modes Automatic, Manual and Standby. When the spa is running in automatic
mode, pressing the pump button will deactivate auto mode and set the pump running in Manual Mode.
The auto LED is orange when auto mode is enabled and off when in Manual Mode. When the pump is
in standby mode all indicator LED’s are off.
Push 1 (Manual Mode)
Push 2 (Standby Mode)
Push 3 (Auto Mode)
Notes:
1) If Pump 1 is left in ”Manual or “Standby” modes it will automatically revert to “Auto” mode after 90
minutes.
2) There is no direct user control over the heater. The heater may come on automatically whenever
Pump 1 is on.
3.2 Pump 1 (Single speed pump, 24hr circulation pump fitted)
Pushing the pump button two times turns the pump on and then off. The pump LED is green when the
pump is running and off when the pump is off.
Push 1 (Pump on)
Push 2 (Pump off)
Notes:
1) If Pump 1 is left on, it will automatically switch off after 20 minutes.
2) There is no direct user control over the heater. The heater may come on automatically whenever
the 24hr circulation pump is on.
3) If the heater element is on, running the pump may cause the heater to load shed and switch off. If
this occurs the heater will come back on approximately 5 seconds after the pump is deselected.