background image

4 Auxiliary Air Button

The Air Button controls anauxiliary air blower. It is used to turn the blower on and off, and select
different operating modes if a Spa Power Variable-Speed Blower (SPVSB) has been fitted. 2 pushes
(STD) or 4 pushes (SPVSB) of the air button cycles the blower as follows: Note:In some spas an
additional jet pump or pool light etc may be fitted instead of a standard air blower.

Standard Air Blower (STD)

Push 1 - Blower ON
Push 2 - Blower OFF

Spa Power Variable-Speed Blower (SPVSB) (if fitted)

Note: If left on, this accessory will automatically switch off after 20 minutes. If the heater
element is on, switching on this accessory may cause the heater to loadshed and switch off.
This is to keep the total power load to a safe level.

4.1 Adjustable Speed Mode (SPVSB only)

If a Spa Power Variable-Speed Blower is fitted, the spa user has the ability to adjust the blower speed to any desired setting.

The Up and Down buttons are used to set the desired blower speed. Note: If the blower is in Full Speed or Oscillating modes

then pushing the Up or Down button will put it into Adjustable Speed mode and then adjust the speed.

Step 1) Press Air Button twice to set Adjustable Speed Mode

Step 2) Press Up

to increase speed of blower

Step 3) Press Down

to decrease speed of blower

Push 4 - Blower OFF (Default State)

AIR

No

Light

Push 1 - Blower ON (Full Speed)

Push 2 - Blower ADJUSTABLE (Adjustable Speed)

Push 3 - Blower OSCILLATING (Oscillating Speed)

AIR

Red

Light

Orange

Light

AIR

AIR

Green

Light

2 Temperature Control

The Spa Power controller automatically controls the pump and heater to filter the water and maintain it
at the desired temperature set by the user (see below). The user can leave the system to look after the
spa and know it will be at the correct temperature when ever he or she wants to use it.

2.1 Adjusting Set Temperature

The Spa Power controller gives the user direct control of the pool temperature from the poolside
control panel. Holding down the Up or Down button will adjust the temperature set point as shown on
the digital readout. There is a slight delay before the buttons operate to reduce the risk of accidental
adjustment. The pool temperature will be maintained very close to the set temperature.

UP

Increase the set temperature by 0.5

o

C per beep (Max = 41.5

o

C)

DOWN

Decrease the set temperature by 0.5

o

C per beep (Min = 10.0

o

C)

Default Display

The display normally shows the temperature set point, unless the optional in pool temperature sensor
is fitted in which case the sensed water temperature is displayed. In either case the temperature set
point will be displayed while being adjusted as describe dabove.

2.2 Non-Default Display Value

The non-default display value (either sensed water temperature
or temperature set point) can be checked if necessary by
pressing the Up &Down buttons simultaneously.

2.3 Heating Mode Selection (24hr circ pump not fitted)

In addition to the temperature setting the user can select the preferred heating mode. The two
available heating modesare...
1. Demand Heating (displayed as Ht.d).This is the default setting in which the pump and heater will

come on automaticallywheneverthetemperaturedropsslightlybelowthesetpoint.

2. FiltrationOnlyHeating(displayedasHt.F).In this mode the pump and heater will come on

automatically no more than once per hour to filter and heat the water. This mode is provided as an
option for those who prefer to limit the natural cycling of the system.

To select the heating mode first press the Pump and Down buttons simultaneously to display the
current heating

mode, then press and hold the Up or Down buttons to change modes.

AIR

Light turns

to orange

Page 8

Page 5