beautypg.com

Tank pre-charge, Installation – Davey SUPERCELL 60F, 80F, 100F, 130F, 200F, & 250F PRESSURE TANKS User Manual

Page 3

background image

- 6 -

- 3 -

Tank Pre-Charge

For correct operation pressure tanks should be pre-charged as follows:
• Pressure switch controlled pumps with differential pressure set at 140 kPa (20

psi), pre-charge the tank to 15kPa (2 psi) below the cut in pressure.

• For pumps controlled by pressure switches with higher differential pressures,

electronic controls or variable speed controls, pre-charge the tank to 65% of

the maximum system pressure.

• Pressure tanks installed on main pressure, pre-charge should be set at the

mains pressure.

• For hot water expansion, pre-charge should be set at the mains pressure.

For your convenience, this pressure tank has been factory set at 140 kPa (20 psi).

Installation

These units have the inlet positioned on the bottom of the tank. Ensure that any

fittings used firmly retain the pipe or hose connected. Thread tape should be

used on all threads.
The tank should be placed on a firm base. If vibration is likely to occur in the

vicinity the tank should be mounted on a resilient mount.
In order to ensure your tank provides its maximum service life it should always

be installed in a covered, dry position. The tank should not be allowed to rub

against any surrounding hard surfaces, such as walls, etc.

NOTE: To avoid possible water damage to property from ruptured

pipes, leaking connections, worn/leaking pump seals, etc., pumps and

associated equipment (including this Supercell Pressure Tank) must be

installed on a well drained site or in a properly constructed water proof

enclosure with drain tray.

CAUTION: Never over-charge the tank and use air at
ambient temperature only!

Nominal Draw Off Capacity in Litres

Dimensions

Tank Model

Tank

Capacity

(litres)

Max

Pressure Rating (kPa)

Pressure Switch Range kPa (psi)

Diameter

(mm)

Height (mm)

Inlet

150-250 (22-36)

150-300 (22-44)

200-400 (29-58)

250-400 (36-58)

250-500 (36-73)

300-600 (44-88)

500-800 (73-116)

Size

(BSP male)

Position

Super

cell 60F

60

860

16.1

21.2

22.8

17.2

23.9

24.8

26.6

421

649

1”

Bottom

Super

cell 80F

80

860

21.5

28.2

30.4

23.0

31.9

28.7

35.5

421

865

1”

Bottom

Super

cell 100F

100

860

26.3

34.5

37.3

28.3

39.3

41.3

44.3

421

980

1”

Bottom

Super

cell 130F

170

860

34.9

45.8

49.4

37.3

51.8

53.6

42.3

421

1211

1”

Bottom

Super

cell 200F

200

860

53.7

70.5

76.0

57.4

79.8

82.5

65.0

546

1098

1

1

/

4

Bottom

Super

cell 250F

250

860

67.1

88.1

95.0

71.8

99.7

103.1

81.3

546

1303

1

1

/

4

Bottom

Note: When installing a Supercell Tank and/or associated pump system
inside a building, allowance for possible high pressure leakage MUST be
made.

Note: In order to carry out routine maintenance the Supercell Pressure
Tank MUST be easily accessible to the end user or home owner.

I

Installation Inside Buildings: To cater for possible plumbing or tank failure,

the installation must include an enclosure that will capture any water

spraying from the tank and direct it into a properly constructed drain tray.