Davey Speedman Compact Constant Water Pressure Systems User Manual
Page 13

13
MESSAGE
MESSAGE MEANING
PUMP STATE
WHAT TO DO
..STOP CC......
• After 10 reset attempts
for short circuit ph-ph-gnd
of the electropump
Off
• For reset is necessary to
contact Davey technical
support
High temperature
• Water temperature above
75ºC
• Automatic reset when the
temperature falls to under
60ºC
Off
• Check that the incoming
water temperature
is within the product
specifications
• Check and restore the
correct pump priming
condition
Press.Insuff......
• High flow and very low
pressure
• Automatic reset
• (Set at the factory for 1
resetting attempt every 5
minutes if unsuccessful
the reset operation will
be attempted every 50
minutes for 24 times.
After which the system
will remain in permanently
blocked state)
Off
• Eliminate the high flow,
usually a broken pipe
• Restore correct pump
priming condition
• Check that any inline
filters are not clogged
Reset:
1 Disconnect the power
supply
2 Wait for the display to
switch off
3 Restore the power supply
No water......
• Lack of water found
• Electro-pump off
• Automatic and
programmable reset
• (Set at the factory for 5
resetting attempt every 5
minutes if unsuccessful
the reset operation will
be attempted every 50
minutes for 24 times.
After which the system
will remain in permanently
blocked state)
Off
• Check that the water is
present in the supply
• Restore correct pump
priming condition
• Check that any inline
filters are not clogged
Reset:
1 Disconnect the power
supply
2 Wait for the display to
switch off
3 Restore the power supply
ProSensor Fault.
• A pressure sensor fault
has been found
Off
• Consult the assistance
service
...continued overleaf.